m+Medelevator.RU
← Поиск публикаций
Journal of refractive surgery (Thorofare, N.J. : 1995) · 2012

Comparison of the visual outcomes and OPD-scan results of AMO Tecnis toric and Alcon Acrysof IQ toric intraocular lenses.

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ferreira Tiago B, Almeida Ana

Аннотация

PURPOSE: To compare the visual outcomes and wavefront analyses of patients who underwent cataract surgery with the implantation of a Tecnis toric intraocular lens (IOL) (Abbott Medical Optics) with those patients who received an Acrysof IQ toric IOL (Alcon Laboratories Inc).

METHODS: The study included 40 eyes from 26 patients with regular corneal astigmatism between 1.00 and 3.00 diopters (D) who were undergoing phacoemulsification with implantation of a toric IOL. Patients were randomized into two groups (20 eyes in each group): one group received the Tecnis toric IOL (Tecnis group) and one group received the Acrysof IQ toric IOL (Acrysof group). Over a 2-month follow-up period, the main outcome measures were uncorrected (UDVA) and corrected distance visual acuity (CDVA), spherical equivalent refraction, residual astigmatism, rotational stability of the IOL, and higher order aberrations, measured with a dynamic retinoscopy aberrometer.

RESULTS: At 2-month follow-up, UDVA, CDVA, spherical equivalent refraction, and residual astigmatism showed no statistically significant between-group differences (P=.834, P=.178, P=.447, and P=.166, respectively). No eye had IOL rotation >10°. The toric IOL axis misalignment was similar in both groups (3.15°±2.62° in the Tecnis group and 3.25°±2.04° in the Acrysof group, P=.265). No statistically significant between-group differences were noted for all ocular aberrometry values, except for spherical aberration, which was higher in the Acrysof group (P=.029).

CONCLUSIONS: Both studied IOLs promoted good postoperative UDVA, CDVA, and refractive results. Rotational stability was excellent for both IOLs. Postoperative spherical aberration was higher for the Acrysof toric IOL; however, this difference did not seem to affect overall visual quality.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты