DOI 10.3928/1081597x-20120522-01
Outcomes of refractive surgery in patients with topographic superior corneal steepening.
Аннотация
PURPOSE: To evaluate the outcomes of refractive surgery in patients with topographic superior corneal steepening.
METHODS
This retrospective, noncomparative, interventional, clinical study included 16 patients (29 eyes) with persistent superior corneal steepening as a variation of corneal curvature (inferior to superior topographic corneal difference of at least 1.00 diopter [D] at a 3-mm zone) not related to any underlying disease or condition who underwent corneal refractive surgery. Refractive, keratometric, and visual outcomes were evaluated preoperatively and at 1, 3, 6, 12, and 24 months postoperatively.
RESULTS
Twenty-two eyes underwent photorefractive keratectomy and 7 eyes underwent LASIK. Mean follow-up was 27.38±2.37 months (range: 25 to 32 months). Mean preoperative inferior to superior keratometric difference was 1.61±0.36 D (range: 1.20 to 2.63 D). Mean preoperative spherical equivalent refraction was -4.45±1.66 D (range: -2.25 to -8.00 D), which decreased to -0.09±0.61 D (range: +0.75 to -1.38 D) (P<.05) at last follow-up. Mean preoperative topographic corneal astigmatism was 1.44±0.79 D (range: 0.52 to 3.83 D), which decreased to 0.66±0.39 D (P<.05) 3 months postoperatively and remained stable during follow-up (P<.54). Mean preoperative uncorrected distance visual acuity and corrected distance visual acuity in logMAR units were 1.57±0.62 and 0.02±0.06, respectively, which improved at last follow-up to 0.00±0.05 and -0.02±0.04, respectively. No intra- or postoperative complications were noted; specifically, no patients developed postoperative ectasia.
CONCLUSIONS
Corneal refractive surgery in patients with isolated topographic superior corneal steepening provided acceptable refractive and visual outcomes without any intra- or postoperative complications. Diligence is required to screen for the potential of ectatic corneal disorders in this population. Photorefractive keratectomy may be a safer option for these patients than LASIK.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.