Intrastromal corneal ring segment implantation to correct astigmatism after penetrating keratoplasty.

Coscarelli Sandro, Ferrara Guilherme, Alfonso Jose F, Ferrara Paulo, Merayo-Lloves Jesús, Araújo Luana P N, Machado Aydano P, Lyra João Marcelo, Torquetti Leonardo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical outcomes of implantation of Ferrara intrastromal corneal ring segments (ICRS) in patients with astigmatism after penetrating keratoplasty (PKP).

SETTING

Private clinic, Belo Horizonte, Brazil.

DESIGN

Retrospective consecutive case series.

METHODS

Chart records of post-PKP patients who had ICRS implantation from May 2005 to September 2009 were retrospectively reviewed. The following parameters were studied: corrected distance visual acuity (CDVA), keratometry (K) values, spherical equivalent (SE), spherical refractive error, corneal topographic astigmatism, minimum K, and maximum K.

RESULTS

The study evaluated 59 eyes (54 patients). The mean CDVA (logMAR) improved from 0.45 ± 0.17 (SD) (range 0.18 to 1.00) to 0.30 ± 0.17 (range 0.00 to 1.00). The mean SE was -6.34 ± 3.40 diopters (D) (range 0.37 to -16.50 D) preoperatively and -2.66 ± 2.52 D (range 0.87 to -10.50 D) postoperatively. The mean spherical refractive error decreased from -7.10 ± 3.07 D (range 2.15 to 16.68 D) preoperatively to -3.46 ± 2.05 D (range 0.88 to 10.79 D) postoperatively. No patient lost visual acuity. The mean corneal topographic astigmatism decreased from 3.37 ± 1.51 D preoperatively to 1.69 ± 1.04 D postoperatively. The mean maximum K value decreased from 48.09 ± 2.56 D to 44.17 ± 2.67 D and the mean minimum K value, from 44.90 ± 2.54 D to 42.46 ± 2.63 D. All changes were statistically significant (P<.0001).

CONCLUSION

Intrastromal corneal ring segments effectively reduced corneal cylinder in patients with astigmatism after PKP.

Для цитирования: Coscarelli Sandro, Ferrara Guilherme, Alfonso Jose F, Ferrara Paulo, Merayo-Lloves Jesús, Araújo Luana P N, Machado Aydano P, Lyra João Marcelo, Torquetti Leonardo. Intrastromal corneal ring segment implantation to correct astigmatism after penetrating keratoplasty.. Journal of cataract and refractive surgery. 2012. DOI: 10.1016/j.jcrs.2011.12.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.