MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2009.11.004

Медицинская библиотека · American journal of ophthalmology · 2010

Test-retest reliability of health-related quality-of-life questionnaires in adults with strabismus.

Leske David A, Hatt Sarah R, Holmes Jonathan M

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report the test-retest variability of two health-related quality-of-life instruments: the new Adult Strabismus 20 (AS-20) and the National Eye Institute 25-item Visual Function Questionnaire (NEI VFQ-25), in adults with strabismus.

DESIGN

Prospective case series.

METHODS

Fifty-five adult patients in a clinical practice with stable strabismus completed the AS-20 and the NEI VFQ-25 at 2 visits, without intervening treatment. Questionnaires were completed the second time either at a subsequent office visit, immediately before surgery, or by mail. Intraclass correlation coefficients were calculated. Ninety-five percent limits of agreement and 95% confidence intervals around the 95% limits of agreement also were calculated.

RESULTS

There was excellent agreement of overall questionnaire scores for the AS-20 (intraclass correlation coefficient, 0.92) and NEI VFQ-25 (intraclass correlation coefficient, 0.94). The 95% limits of agreement for overall scores were 14.3 points (95% confidence interval, 10.9 to 17.7) for the AS-20 and 11.1 points (95% confidence interval, 8.5 to 13.8) for the NEI VFQ-25. The lower test-retest variability of the VFQ-25 seemed to be partly the result of ceiling effects with many scores at the normal end of the range.

CONCLUSIONS

The new AS-20 and the NEI VFQ-25 show excellent test-retest reliability in adults with strabismus. Change exceeding 95% limits of agreement (14 points on the AS-20 and 11 points on the VFQ-25) is indicative of real change in an individual patient. The AS-20 may be more useful than the VFQ-25 because it is less prone to ceiling effects in adults with strabismus.

Для цитирования: Leske David A, Hatt Sarah R, Holmes Jonathan M. Test-retest reliability of health-related quality-of-life questionnaires in adults with strabismus.. American journal of ophthalmology. 2010. DOI: 10.1016/j.ajo.2009.11.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.