MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/02713680903421186

Медицинская библиотека · Current eye research · 2010

Reverse geometry rigid gas permeable contact lens wear reduces high-order aberrations and the associated symptoms in post-LASIK patients.

Tan Gang, Chen Xiaolian, Xie Ruo Zhong, He Hong, Liu Qiong, Guo Yingzhuo, Liao Aiping, Zhong Xingwu

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: This study evaluated the efficacy of custom-made reverse geometry rigid gas permeable (RGP) contact lenses in the control of symptoms related to increased wavefront aberrations after LASIK correction of myopia.

MATERIALS AND

METHODS

Twenty-eight myopes treated with LASIK were assessed for post-LASIK symptoms (declined night vision, glare, halos and/or monocular diplopia) and corneal topography. A set of RGP contact lenses was selected as trial lenses based on the matching between the lens and the patient's corneal topography. If the fluorescein pattern between the trial lens and the corneal surface showed a central alignment, a mid-peripheral bearing and peripheral clearance and if the patient felt comfortable with the lens wear, a duplicated lens was ordered for the patient. Otherwise, a lens satisfied with corneal topography of the patient and clinical judgment was used. Visual acuity (VA) and wavefront aberrations were measured after the lens wear.

RESULTS

The custom-made lenses well matched the host cornea with no dislodgment in all subjects. The post-LASIK eyes showed an increase of 1 Snellen line in VA (from 0.90 +/- 0.33 to 1.11 +/- 0.24) and a significant improvement in all symptoms after the lens wear. The total higher-order aberration is significantly reduced after the lens wear with at least 70% reduction in either spherical aberration, coma, third or fourth aberration but only 33% reduction in the fifth aberration.

CONCLUSIONS

Reverse geometry RGP lenses with the design based on individual topographic data can improve visual performance of post-LASIK eyes by reducing higher order aberrations.

Для цитирования: Tan Gang, Chen Xiaolian, Xie Ruo Zhong, He Hong, Liu Qiong, Guo Yingzhuo, Liao Aiping, Zhong Xingwu. Reverse geometry rigid gas permeable contact lens wear reduces high-order aberrations and the associated symptoms in post-LASIK patients.. Current eye research. 2010. DOI: 10.3109/02713680903421186.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.