Detection and identification of Actinobacillus pleuropneumoniae serotype 5 by multiplex PCR.

Lo T M, Ward C K, Inzana T J

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

Serotyping of Actinobacillus pleuropneumoniae is based on detection of the serotype-specific capsular antigen. However, not all isolates can be serotyped, and some may cross-react with multiple serotyping reagents. To improve sensitivity and specificity of serotyping and for early detection, a multiplex PCR assay was developed for detection of A. pleuropneumoniae and identification of serotype 5 isolates. DNA sequences specific to the conserved export and serotype-specific biosynthesis regions of the capsular polysaccharide of A. pleuropneumoniae serotype 5 were used as primers to amplify 0.7- and 1.1-kb DNA fragments, respectively. The 0.7-kb fragment was amplified from all strains of A. pleuropneumoniae tested with the exception of serotype 4. The 0.7-kb fragment was not amplified from any heterologous species that are also common pathogens or commensals of swine. In contrast, the 1.1-kb fragment was amplified from all serotype 5 strains only. The assay was capable of amplifying DNA from less than 10(2) CFU. The A. pleuropneumoniae serotype 5 capsular DNA products were readily amplified from lung tissues obtained from infected swine, although the 1.1-kb product was not amplified from some tissues stored frozen for 6 years. The multiplex PCR assay enabled us to detect A. pleuropneumoniae rapidly and to distinguish serotype 5 strains from other serotypes. The use of primers specific to the biosynthesis regions of other A. pleuropneumoniae serotypes would expand the diagnostic and epidemiologic capabilities of this assay.

Для цитирования: Lo T M, Ward C K, Inzana T J. Detection and identification of Actinobacillus pleuropneumoniae serotype 5 by multiplex PCR.. Journal of clinical microbiology. 1998. DOI: 10.1128/jcm.36.6.1704-1710.1998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.