MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s441172

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2023

Biometric Indicators for Maximizing Intermediate Vision with a Monofocal IOL.

Micheletti J Morgan, McCauley Matthew B, Duncan Nicole, Hall Brad

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine refractive or biometric variables that might be predictive of increased intermediate vision in patients receiving an Eyhance monofocal intraocular lens (IOL).

METHODS

This prospective, single-center, bilateral, non-randomized, open-label, observational study included a total of 110 subjects (220 eyes). Subjects had been previously bilaterally implanted with an Eyhance monofocal IOL (Johnson & Johnson Vision Care, Inc.) and were later divided into 2 groups based on their postoperative visual acuity. Subjects that had binocular distance corrected intermediate visual acuity (DCIVA) of 0.2 logMAR or better were classified into the Enhanced Group, and the remaining subjects were classified into the Non-Enhanced Group. Refractive outcomes and biometric measurements were compared between groups.

RESULTS

The number of subjects in each group was 61 for the Enhanced Group, and 49 for the Non-Enhanced Group. There were significant differences in pupil size between groups, with pupil sizes in the Enhanced Group significantly smaller than in the Non-Enhanced Group (p < 0.01). Subjects also reported significantly more dysphotopsias in the Non-Enhanced Group compared to the Enhanced Group (p = 0.03). Multiple regression analysis identified pupil size and axial length as significant predictors of increased monocular intermediate vision.

CONCLUSION

The results of this study suggest that pupil size could be a predictor of increased intermediate vision in a patient receiving an Eyhance monofocal IOL.

Для цитирования: Micheletti J Morgan, McCauley Matthew B, Duncan Nicole, Hall Brad. Biometric Indicators for Maximizing Intermediate Vision with a Monofocal IOL.. Clinical ophthalmology (Auckland, N.Z.). 2023. DOI: 10.2147/opth.s441172.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.