MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001375

Медицинская библиотека · Journal of cataract and refractive surgery · 2024

Surgical outcomes of intraocular lens iris suture fixation in eyes with residual capsule support.

Alsetri Hasan, Masket Samuel, Fram Nicole, Schoen Marisa, Cabang Julieanne, Pagal Jared, Kwong Stephen, Fram Ashlyn, Sandoval Hector

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and refractive outcomes of eyes after intraocular lens (IOL) iris suture fixation (ISF).

SETTING

Private practice, Los Angeles, California.

DESIGN

Nonrandomized and unmasked retrospective chart review.

METHODS

Eyes that underwent IOL exchange or repositioning with ISF with at least 270 degrees of capsular support were included. Eyes with less than 270 degrees of capsular support and eyes with iris damage were excluded. The primary outcome measures included incidence of cystoid macular edema (CME), IOL dislocation requiring refixation, and chronic inflammation. Secondary outcome measures included worsening intraocular pressure (IOP) control, retinal tear or detachment, worsening of corrected distance visual acuity (CDVA), and corneal decompensation. Refractive outcomes for 26 subgrouped eyes included mean and median spherical equivalent refraction accuracy (SERA), and percentage of eyes within 0.5 diopter (D) and 1 D of the refractive target.

RESULTS

The study included 53 eyes of 50 patients. CME: 2/53 (3.8%), IOL dislocation requiring refixation: 2/53 (3.8%), chronic inflammation: 1/53 (1.9%), worsening IOP control: 5/53 (9.4%), retinal tear or detachment: 2/53 (3.8%). No patient experienced worsening of CDVA from baseline or corneal decompensation. Mean SERA ± SD -0.35 ± 0.29 D, median SERA -0.37 D. Of the 26 eyes subgrouped for refractive analysis, 73% were within 0.5 D and 100% were within 1 D of the desired refractive outcome.

CONCLUSIONS

ISF can offer stability for sulcus-fixated IOLs provided there is some residual capsule support. Although there are measurable complications, there is a relatively low side effect profile. The refractive error tended to be myopic, indicating the need for further refinement of IOL power predictive formulas.

Для цитирования: Alsetri Hasan, Masket Samuel, Fram Nicole, Schoen Marisa, Cabang Julieanne, Pagal Jared, Kwong Stephen, Fram Ashlyn, Sandoval Hector. Surgical outcomes of intraocular lens iris suture fixation in eyes with residual capsule support.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.