MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ceo.14315

Медицинская библиотека · Clinical & experimental ophthalmology · 2023

Unilateral intraindividual comparison and bilateral performance of a monofocal spherical and diffractive extended depth of field intraocular lens mix-and-match approach.

Wendelstein Jascha A, Casazza Marina, Reifeltshammer Sophia, Riaz Kamran, Pantanelli Seth, Mariacher Siegfried, Seiler Theo G, Kohnen Thomas, Bolz Matthias

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To evaluate the intraindividual visual performance of a spherical and extended depth of field (EDOF) IOL used in a mix-and-match approach.

METHODS

Single centre (tertiary care centre), retrospective consecutive case series. Included patients had uneventful cataract surgery with implantation of a spherical monofocal IOL (CT Spheris 204) in the dominant eye and a diffractive EDOF IOL (AT LARA 829) in the non-dominant eye. Monocular and binocular defocus curves and visual acuity at various distances were assessed. In addition, binocular reading speed, contrast sensitivity, and patient satisfaction using QOV, Catquest 9SF, and glare/halo questionnaires are reported.

RESULTS

A total of 29 patients (58 eyes) were included. We observed significant intra-individual differences for monocular DCIVA, DCNVA, UIVA, and UNVA. There were no differences in monocular BCDVA or UDVA. The monocular defocus curves for the two IOLs significantly differed at defocus steps between -1.0 and -3.5 D. 93.10% of patients reported they would opt for the same combination of IOLs.

CONCLUSION

Excellent uncorrected and corrected distance visual acuity was demonstrated in both groups. The mix-and-match approach described in this study yielded good intermediate vision and improved near vision with high-patient satisfaction.

Для цитирования: Wendelstein Jascha A, Casazza Marina, Reifeltshammer Sophia, Riaz Kamran, Pantanelli Seth, Mariacher Siegfried, Seiler Theo G, Kohnen Thomas, Bolz Matthias. Unilateral intraindividual comparison and bilateral performance of a monofocal spherical and diffractive extended depth of field intraocular lens mix-and-match approach.. Clinical & experimental ophthalmology. 2023. DOI: 10.1111/ceo.14315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.