Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023
Optical characterization and through-focus performance of two advanced monofocal intraocular lenses.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Salgado-Borges José, Borges Anabela, Ferreira Isabel, González-Méijome José Manuel, Faria-Ribeiro Miguel
Аннотация
PURPOSE: To compare the refractive power profile, subjective depth-of-field and objective optical quality of two advanced monofocal intraocular lenses (IOLs) designed to improve intermediate vision.
METHODS: This prospective study evaluated forty-six eyes of twenty-three patients, aged 54-68 years, binocularly implanted with two monofocal enhanced intraocular lenses (IOLs), the Tecnis Eyhance and the Physiol Isopure. Subjective through-focus visual acuity curves were obtained by placing trial lenses in front of the eye while wearing its best spherical-cylindrical correction for distance. Objective optical quality was defined as the area under the modulation transfer function, calculated from the wavefront maps measured with a high-resolution aberrometer. The optical design of both lenses was compared based on their refractive power profiles measured with the lenses immersed in saline solution.
RESULTS: Both lenses have progressive aspherical geometries, in which the sagittal power decreases rapidly from the center to the edge of the optical zone. Mean monocular through-focus curves show a best corrected distance visual acuity of - 0.02 logMAR with both lenses. Through-focus visual acuity was marginally higher for the Eyhance, with a difference of 1 letter at the defocus position of - 0.5D and 3 letters between - 1.0D and - 2.0D. Objective assessment of optical quality revealed only a difference of about 2 points in MTF area at distance.
CONCLUSION: Both IOLs use a similar approach to improve intermediate vision. The Eyhance showed marginally better subjective performance than the Isopure at the target vergences between - 1.00D and - 2.00D, although these results did not reach statistical significance and were not replicated by the objective findings.
METHODS: This prospective study evaluated forty-six eyes of twenty-three patients, aged 54-68 years, binocularly implanted with two monofocal enhanced intraocular lenses (IOLs), the Tecnis Eyhance and the Physiol Isopure. Subjective through-focus visual acuity curves were obtained by placing trial lenses in front of the eye while wearing its best spherical-cylindrical correction for distance. Objective optical quality was defined as the area under the modulation transfer function, calculated from the wavefront maps measured with a high-resolution aberrometer. The optical design of both lenses was compared based on their refractive power profiles measured with the lenses immersed in saline solution.
RESULTS: Both lenses have progressive aspherical geometries, in which the sagittal power decreases rapidly from the center to the edge of the optical zone. Mean monocular through-focus curves show a best corrected distance visual acuity of - 0.02 logMAR with both lenses. Through-focus visual acuity was marginally higher for the Eyhance, with a difference of 1 letter at the defocus position of - 0.5D and 3 letters between - 1.0D and - 2.0D. Objective assessment of optical quality revealed only a difference of about 2 points in MTF area at distance.
CONCLUSION: Both IOLs use a similar approach to improve intermediate vision. The Eyhance showed marginally better subjective performance than the Isopure at the target vergences between - 1.00D and - 2.00D, although these results did not reach statistical significance and were not replicated by the objective findings.