DOI 10.1097/j.jcrs.0000000000001371
Complications of foldable intraocular lenses requiring explantation or secondary intervention: 2022 survey with update of long-term trends.
Аннотация
PURPOSE: To assess the complications that resulted in the explantation or secondary intervention with foldable intraocular lenses (IOLs).
SETTING
University setting, Salt Lake City, Utah.
DESIGN
Survey study.
METHODS
For the 25th consecutive year, surgeons were surveyed regarding complications associated with foldable IOLs requiring explantation or secondary intervention over the 2022 calendar year. These forms were made available online using the ASCRS and ESCRS websites and a fax-on-demand service. Surgeons completed 1 survey for each foldable IOL requiring explantation or secondary intervention. Further analysis determined complication trends related to specific IOL styles, materials, and types over the past 16 years (2007 to 2022).
RESULTS
103 completed surveys were returned in 2022 contributing to a total of 1627 tabulated surveys since 2007. In the 2022 survey, dislocation/decentration continued to be the most common complication overall. Glare/optical aberrations was a common complication associated with multifocal IOLs continuing a 16-year trend. In addition, hydrophilic acrylic IOLs as well as some silicone lenses in eyes with asteroid hyalosis demonstrated calcification as the most common complication necessitating explantation.
CONCLUSIONS
Dislocation/decentration remains the leading cause of explantation in most IOL types. Glare/optical aberrations continue to be an associated complication of multifocal IOLs suggesting this ongoing issue has yet to be resolved with this type of IOL. In addition, calcification of hydrophilic acrylic lenses and silicone lenses is a rare event but continues to occur.