MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001363

Медицинская библиотека · Journal of cataract and refractive surgery · 2024

Evaluation of corneal power from an AS-OCT thick lens model and ray tracing: reliability of the keratometer index.

Langenbucher Achim, Hoffmann Peter, Cayless Alan, Wendelstein Jascha, Szentmáry Nóra

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate and compare different strategies of corneal power calculations using keratometry, paraxial thick lens calculations and ray tracing.

SETTING

Tertiary care center.

DESIGN

Retrospective single-center consecutive case series.

METHODS

Using a dataset with 9780 eyes of 9780 patients from a cataractous population the corneal front (Ra/Qa) and back (Rp/Qp) surface radius/asphericity, central corneal thickness (CCT), and entrance pupil size (PUP) were recorded using the Casia 2 tomographer. Beside keratometry with the Zeiss (PK Z ) and Javal (PK J ) keratometer index, a thick lens paraxial formula (PG) and ray tracing (PR) was implemented to extract corneal power for pupil sizes from 2 mm to 5 mm in steps of 1 mm and PUP.

RESULTS

With PUP PK Z /PK J overestimates the paraxial corneal power PG in around 97%/99% of cases and PR in around 80% to 85%/99%. PR is around 1/6 or 5/6 diopters (D) lower compared with PK Z or PK J . For a 2 mm pupil PR is around 0.20/0.91 D lower compared with PK Z /PK J and for a 5 mm pupil PR is comparable with PK Z (around 0.03 D lower) but around 0.70 to 0.75 D lower than PK J .

CONCLUSIONS

"True" values of corneal power are mostly required in lens power calculations before cataract surgery, and overestimation of corneal power could induce trend errors in refractive outcome with axial length and lens power if compensated with the effective lens position.

Для цитирования: Langenbucher Achim, Hoffmann Peter, Cayless Alan, Wendelstein Jascha, Szentmáry Nóra. Evaluation of corneal power from an AS-OCT thick lens model and ray tracing: reliability of the keratometer index.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001363.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.