MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-023-06283-y

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023

Combined versus standalone XEN45 Gel Stent implantation in either phakic or pseudophakic patients: a case-matched study.

Kiessling David, Rennings Corinna, Hild Matthias, Lappas Alexandra, Dietlein Thomas Stefan, Roessler Gernot Franz, Widder Randolf Alexander

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine differing outcomes among either phakic or pseudophakic patients who received standalone XEN45 Gel Stent (Allergan, an AbbVie Company, CA, USA) implantation and patients who underwent combined surgery with phacoemulsification.

METHODS

This retrospective single-center study involved 180 eyes of 180 participants who underwent XEN45 Gel Stent implantation, of which 60 eyes received combined surgery with phacoemulsification (combined group). Standalone stent implantation was performed on 60 phakic (phakic group) and on 60 pseudophakic eyes (pseudophakic group). The groups were matched in a ratio of 1:1:1 based on multiple criteria. Successful surgery was defined by three scores: IOP at the longest follow-up of < 21 mmHg (Score A) or < 18 mmHg (Score B) and an IOP reduction > 20% or IOP ≤ 15 mmHg and an IOP reduction ≥ 40% (Score C). In all scores, one open conjunctival revision was allowed, and additional repeat surgery was considered a failure.

RESULTS

After an average follow-up time interval of 20.6 ± 12.6 months, there was a mean IOP-reduction by 37% among the entire cohort. Comparative analysis between the three groups did not show significant differences regarding postoperative IOP, postoperative medication score, side effects, revision rate, repeat surgery rate or success rate. A dysfunctional stent was detected in eight eyes (4%) during open conjunctival revision in 76 eyes.

CONCLUSION

The clinical endpoints investigated did not differ significantly among either phakic or pseudophakic patients who received standalone stent implantation and patients who underwent combined surgery. However mean latency between primary stent implantation and first revision surgery after combined surgery was markedly shorter.

Для цитирования: Kiessling David, Rennings Corinna, Hild Matthias, Lappas Alexandra, Dietlein Thomas Stefan, Roessler Gernot Franz, Widder Randolf Alexander. Combined versus standalone XEN45 Gel Stent implantation in either phakic or pseudophakic patients: a case-matched study.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2023. DOI: 10.1007/s00417-023-06283-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.