Loss of Pace Capture on the Ablation Line During Pulmonary Vein Isolation versus "Dormant Conduction": Is Adenosine Expendable?

Schaeffer Benjamin, Willems Stephan, Sultan Arian, Hoffmann Boris A, Lüker Jakob, Schreiber Doreen, Akbulak Ruken, Moser Julia, Kuklik Pawel, Steven Daniel

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Permanent pulmonary vein isolation (PVI) remains an essential goal of ablation therapy in patients with atrial fibrillation. Aim of this study was the intraindividual comparison of unexcitability to pacing along the ablation line versus dormant conduction (DC) as additional procedural endpoints.

METHODS

A total of 58 patients with paroxysmal atrial fibrillation (PAF) underwent PVI by circumferential ablation of ipsilateral pulmonary veins (PVs), followed by testing for DC by adenosine administration. Irrespective of the presence of DC, pacing along the ablation line for left atrium capture was performed and additional radio frequency energy applied if necessary. PVs with initial DC were retested after achieving unexcitability.

RESULTS

PVI was achieved in 224 of 224 PVs. In 33 of 224 PVs (15%) DC was revealed. At 92 of 112 ablation lines (82%) sites of excitability were found. Three (9%) of the initial 33 PVs with DC showed further DC after achieving unexcitability at repeated testing. Thirty-two of 33 assumed areas of unmasked PV-LA reconduction as revealed by DC-testing showed a corresponding site of excitability on the ablation line. After a follow-up of 11.6 ± 3.4 months 79% of patients were free of arrhythmia.

CONCLUSIONS

Pacing for unexcitability can safely identify potential sites of DC and even sites that would have not been detected by testing for DC. Unexcitability, therefore, serves as a suitable and safe procedural endpoint not only for patients with contraindications to adenosine administration. Our data suggest that adenosine may be expendable when achieving unexcitability along the ablation line.

Для цитирования: Schaeffer Benjamin, Willems Stephan, Sultan Arian, Hoffmann Boris A, Lüker Jakob, Schreiber Doreen, Akbulak Ruken, Moser Julia, Kuklik Pawel, Steven Daniel. Loss of Pace Capture on the Ablation Line During Pulmonary Vein Isolation versus "Dormant Conduction": Is Adenosine Expendable?. Journal of cardiovascular electrophysiology. 2015. DOI: 10.1111/jce.12759.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.