DOI 10.1016/j.ijcard.2015.05.089
Pulmonary vein measurements on pre-procedural CT/MR imaging can predict difficult pulmonary vein isolation and phrenic nerve injury during cryoballoon ablation for paroxysmal atrial fibrillation.
Аннотация
OBJECTIVE
We tested the hypothesis that pulmonary vein (PV) measurements on pre-procedural CT/MR imaging can predict difficulty in isolation and phrenic nerve (PN) injury during cryoballoon ablation for paroxysmal atrial fibrillation (AF).
METHODS
Consecutive patients with paroxysmal AF who had pre-procedural CT/MRI and underwent cryoballoon ablation as part of a randomized trial were studied. Imaging was anonymized for blinded analysis of: (1) maximum ostial diameter, (2) minimum ostial diameter, (3) ostial area and (4) ratio of maximum over minimum ostial diameter (eccentricity index). Veins that required more than 2 freezes of at least 200 s duration to isolate or not isolated were defined as difficult to isolate. Loss of PN pacing during right-sided ablation was defined as PN injury. Logistic regression was used to analyze the predictive effect of the measurements on the 2 outcomes.
RESULTS
148 PVs in 38 patients (aged 60 ± 11 years, 76% male) were analyzed. Left inferior PV (LIPV) was most difficult to isolate with 23 out of 37 PVs (62%), and PN injury occurred in 3 of 38 (8%) right superior PV (RSPV). Greater eccentricity index predicted difficulty in isolating LIPV, OR 40.33 (95% CI 1.40 to 1160, p = 0.03) and smaller eccentricity index predicted PN injury in RSPV, OR 0.01 (95% CI 0.01-0.16, p = 0.001).
CONCLUSIONS
Eccentricity index measured from pre-procedural CT/MR imaging can predict difficulty of PV isolation and PN injury during cryoballoon ablation for paroxysmal AF.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.