MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12637

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2015

The Impact of Left Atrial Surface Area and the Second Generation Cryoballoon on Clinical Outcome of Atrial Fibrillation Cryoablation.

Greiss Harald, Berkowitsch Alexander, Wojcik Maciej, Zaltsberg Sergej, Pajitnev Dimitri, Deubner Nikolas, Akkaya Ersan, Güttler Norbert, Hamm Christian, Neumann Thomas, Kuniss Malte

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: In this observational study, we examine the significance of the left atrial (LA) surface area and compare the clinical usage of the Arctic Front Advance (CBA) versus Arctic Front (CB) cryoballoon with the intent to investigate the impact of each in terms of long-term freedom from atrial fibrillation (AF) for patients with nonvalvular AF.

METHODS

Pulmonary vein isolation (PVI) was performed while using a cryoballoon ablation catheter in conjunction with an intraluminal circular diagnostic mapping catheter, Achieve. The consecutive patients ablated with CBA were matched with patients previously ablated with CB, using propensity score matching. The primary endpoint of this observational single-center retrospective study was the first observation of electrocardiogram-documented recurrence of atrial arrhythmias lasting >30 seconds.

RESULTS

The patient demographic data were similar in the CBA- and CB-group (N = 188 patients each group). In all patients in the CBA-group and in 95% of the patients in the CB group, acute procedural PVI of all veins was achieved with the single usage of a 28-mm cryoballoon. The one-year freedom from atrial arrhythmias was significantly better in the CBA- versus the CB-group of patients, 90% versus 64%, respectively. During 15-month clinical follow-up in CBA group, patients with LA area above 23 cm(2) were more likely to experience recurrence of AF (23%) than patients with LA area below 23 cm(2) (7%).

CONCLUSIONS

Comparing one-year outcomes, the CBA is superior to the CB with regards to maintenance of normal sinus rhythm. When using the CBA catheter, an enlarged LA is associated with a higher recurrence of arrhythmia.

Для цитирования: Greiss Harald, Berkowitsch Alexander, Wojcik Maciej, Zaltsberg Sergej, Pajitnev Dimitri, Deubner Nikolas, Akkaya Ersan, Güttler Norbert, Hamm Christian, Neumann Thomas, Kuniss Malte. The Impact of Left Atrial Surface Area and the Second Generation Cryoballoon on Clinical Outcome of Atrial Fibrillation Cryoablation.. Pacing and clinical electrophysiology : PACE. 2015. DOI: 10.1111/pace.12637.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.