MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12634

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2015

Catheter Ablation of Atrial Fibrillation Using Zero-Fluoroscopy Technique: A Randomized Trial.

Bulava Alan, Hanis Jiri, Eisenberger Martin

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Recent advances in 3D mapping systems, such as simultaneous visualization of multiple catheters and contact force measurement, have allowed a significant reduction in fluoroscopic times during radiofrequency (RF) ablation (RFA) procedures. The objective was to investigate whether RFA of paroxysmal atrial fibrillation (PAF) using the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA) and intracardiac echocardiography (ICE) can be performed safely without fluoroscopy.

METHODS AND

RESULTS

Eighty patients with PAF were randomized in a 1:1 ratio to undergo either fluoroscopically guided pulmonary vein isolation (PVI) (X+) or PVI without fluoroscopy (X-). In the X- fluoroscopy group, catheter placement, transseptal puncture, left atrial geometry reconstruction, and PVI were accomplished solely using ICE imaging and CARTO mapping. The total procedure duration and RF application time in both the X- and X+ groups were comparable (92.5 ± 22.9 minutes vs 99.9 ± 15.9 minutes, P = 0.11 and 1785 ± 548 seconds vs 1755 ± 450 seconds, P = 0.79, respectively). Zero fluoroscopic time was achieved in all patients in the X- group with the exception of one patient, where 8 seconds of fluoroscopy was needed to assess proper position of the guide-wire in the femoral vein. No serious procedure-related complications were recorded and no differences in arrhythmia-free survival at 12 months were found between the groups.

CONCLUSION

RFA using ICE imaging and the CARTO 3 mapping system with contact force measurement is capable of eliminating fluoroscopy in patients undergoing PVI. Exclusion of fluoroscopic imaging does not seem to compromise patient safety and does not affect overall procedure duration, RF application time, or mid-term efficacy.

Для цитирования: Bulava Alan, Hanis Jiri, Eisenberger Martin. Catheter Ablation of Atrial Fibrillation Using Zero-Fluoroscopy Technique: A Randomized Trial.. Pacing and clinical electrophysiology : PACE. 2015. DOI: 10.1111/pace.12634.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.