m+Medelevator.RU
← Поиск публикаций
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2014

Predictors of ectopic firing from the superior vena cava in patients with paroxysmal atrial fibrillation.

Клиническое исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Inada Keiichi, Matsuo Seiichiro, Tokutake Ken-ichi, Yokoyama Ken-ichi, Hioki Mika, Narui Ryohsuke, Ito Keiichi, Tanigawa Shin-ichi, Yamashita Seigo, Tokuda Michifumi, Shibayama Kenri, Miyanaga Satoru, Sugimoto Ken-ichi, Yoshimura Michihiro, Yamane Teiichi

Аннотация

PURPOSE: Although catheter ablation targeting the pulmonary vein (PV) is a well-known therapy for patients with paroxysmal atrial fibrillation (PAF), ectopic firings from the superior vena cava (SVC) can initiate PAF. The purpose of this study was to investigate predictors of SVC firing.

METHODS: The subjects included 336 consecutive PAF patients (278 males, age 56.1 ± 10.8 years) undergoing atrial fibrillation (AF) ablation. The appearance of SVC firing was monitored throughout the procedure using a decapolar catheter with multiple electrodes to record electrograms of the coronary sinus and SVC. In addition to PV isolation, SVC isolation was performed only in patients with documented SVC firing.

RESULTS: SVC firing was observed in 43/336 (12.8 %) of the patients, among whom complete isolation of the SVC was achieved in 40/43 (93 %) patients. A lower body mass index (BMI) (22.8 ± 2.8 vs 24.1 ± 3.1 kg/m(2), p = 0.007) and higher prevalence of prior ablation procedures (58 vs 18 %, p = 0.0001) were related to the presence of SVC firing. In a multivariate analysis, a lower BMI (p = 0.012; odds ratio 0.83, 95 % CI 0.72 to 0.96) and history of prior ablation procedures (p < 0.0001; odds ratio 5.37, 95 % CI 2.71 to 10.63) were found to be independent predictors of the occurrence of SVC firing. Among 96 patients undergoing repeat ablation procedures, less PV-left atrial re-conduction was observed in patients with SVC firing than in those without (2.7 ± 1.2 vs 3.2 ± 0.8, p = 0.02).

CONCLUSIONS: The presence of SVC firing in patients with PAF is associated with a history of repeat ablation procedures and lower BMI values.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты