MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12471-014-0595-z

Медицинская библиотека · Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2014

Follow-up of implantable cardioverter-defibrillator therapy: comparison of coronary artery disease and dilated cardiomyopathy.

Verhagen M P, van Boven N, Ruiter J H, Kimman G-J P, Tahapary G J, Umans V A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Since several large trials have proven the effectiveness of implantable cardioverter-defibrillators (ICDs) in patients with left ventricular dysfunction, disadvantages have become more apparent. As the prognosis of patients with cardiovascular diseases is improving, assessment of ICD patients and re-evaluation of the current guidelines is mandatory. We aimed to evaluate differences in mortality and occurrence of (in)appropriate shocks in ICD patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM).

METHODS

In a large teaching hospital, all consecutive patients with systolic dysfunction due to CAD or DCM who received an ICD with and without resynchronisation therapy, were collected in a database.

RESULTS

A total of 320 consecutive patients (age 67 ± 10 years) were classified as CAD patients and 178 (63 ± 11 years) as DCM patients. Median follow-up was 40 months (interquartile range [IQR] 23─57 months). All-cause mortality was 14 % (CAD 15 % vs DCM 13 %). Appropriate shocks occurred in 13 % of all patients (CAD 15 % vs DCM 11 %, p = 0.12) and inappropriate shocks occurred in 10 % (CAD 8 % vs DCM 12 %, p = 0.27). Multivariate analysis demonstrated impaired left ventricular ejection fraction, QRS >120, age ≥75 years and low estimated glomerular filtration rate as predictors for all-cause mortality. Predictors for inappropriate shocks were permanent and paroxysmal atrial fibrillation.

CONCLUSION

Mortality rates were similar in patients with CAD and DCM who received an ICD. Furthermore, no differences were found in the occurrence of appropriate and inappropriate ICD interventions between these patient groups.

Для цитирования: Verhagen M P, van Boven N, Ruiter J H, Kimman G-J P, Tahapary G J, Umans V A. Follow-up of implantable cardioverter-defibrillator therapy: comparison of coronary artery disease and dilated cardiomyopathy.. Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation. 2014. DOI: 10.1007/s12471-014-0595-z.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.