MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12500

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2014

Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQ™): feasibility, acute and short-term efficacy, safety, and impact on postablation silent cerebral ischemia.

Scaglione Marco, Caponi Domenico, Anselmino Matteo, Di Clemente Francesca, Blandino Alessandro, Ferraris Federico, Di Donna Paolo, Ebrille Elisa, Halimi Franck, Leclercq Jean F, Iunco Costanza, Vaudagna Carloeugenio, Cesarani Federico, Gaita Fiorenzo

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Simultaneous multipolar ablation catheters have been proposed to simplify pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (AF). Recently, a new multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™, Biosense Webster Inc., Diamond Bar, CA, USA) combining both 3-dimensional electroanatomic mapping and multipolar open-irrigated ablation capability has been developed. Aim of our study was to assess feasibility, acute and short-term success and safety of PVI by the use of this new technology with particular regard to the incidence of postablation silent cerebral ischemia (SCI).

METHODS AND

RESULTS

Twenty-five patients (76% males; age 57 ± 13 years) with paroxysmal AF underwent PVI using the nMARQ™ catheter. PVI, confirmed by Lasso catheter mapping, was achieved in 100 out of 102 pulmonary veins (98%) identified, and final PVI was obtained in 24 out of 25 (96%) patients. The overall concordance between Lasso and nMARQ™ signals in demonstrating PVI was 78%. No major procedural complications occurred and no patient suffered SCI, on the basis of cerebral magnetic resonance imaging performed before and after the procedure. Following a 6-month follow-up, 17/25 (68%) patients remained free from AF without antiarrhythmic drugs.

CONCLUSIONS

In our preliminary experience, PVI with nMARQ™ catheter appears to be feasible and safe, without incidence of SCI. Long-term clinical efficacy has to be evaluated in further studies.

Для цитирования: Scaglione Marco, Caponi Domenico, Anselmino Matteo, Di Clemente Francesca, Blandino Alessandro, Ferraris Federico, Di Donna Paolo, Ebrille Elisa, Halimi Franck, Leclercq Jean F, Iunco Costanza, Vaudagna Carloeugenio, Cesarani Federico, Gaita Fiorenzo. Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQ™): feasibility, acute and short-term efficacy, safety, and impact on postablation silent cerebral ischemia.. Journal of cardiovascular electrophysiology. 2014. DOI: 10.1111/jce.12500.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.