MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua xin xue guan bing za zhi · 2013

[Clinical characteristics and long-term outcome of non-pulmonary vein foci ablation in patients with paroxysmal atrial fibrillation].

Chen Hong-wu, Chen Ming-long, Yang Bing, Ju Wei-zhu, Zhang Feng-xiang, Gu Kai, Li Ming-fang, Gao Ke-jiang

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the clinical characteristics and long-term results of non-pulmonary veins (PV) trigger ablation in patients with paroxysmal atrial fibrillation (AF).

METHODS

Eighty-six patients [48 men, mean age (52.3 ± 10.2) years] were included in the study. Circumferential pulmonary vein antrum isolation guided by a 3-D mapping system was performed. Aggressive high right atrium programmed stimulation and burst pacing were made before and after isoproterenol infusion. Additional ablation was performed if other trigger foci were found or other sustained tachycardias could be induced.

RESULTS

PV triggers were observed in 59 patients (group I), and non-PV triggers were observed in 27 patients (group II), 12 non-PV triggers were identified during the first procedure. Among them, one was located in the roof of left atrium, 11 were originated from superior vena cava. After a mean follow-up of [37.1 ± 10.4 (range 15-60)] months, the AF recurrence rate was significantly higher in the Group II than in the Group I (55.5% vs. 20.3%, P = 0.001). The number of performed ablation was also significantly in group II than in group I higher difference (1.7 ± 0.8 vs. 1.1 ± 0.4, P < 0.001). In the group II, 15/15 (100%) patients had a repeated ablation procedure for AF recurrence, and 15 patients had new non-PV foci after isoproterenol infusion which were originated from the superior vena cava (n = 11) and coronary sinus (n = 2), respectively. After the second ablation procedure, AF recurrence was observed in three patients, two patients accepted third procedure, the non-PV triggers were located in left atrial septum and coronary sinus, and one patient accepted fourth procedure, the non-PV foci was located in left posterior wall.

CONCLUSIONS

Non-PV foci may occur at any age and the main area is located in the super vena cava, Non-PV serves as a major cause of AF recurrence after successful PVAI.

Для цитирования: Chen Hong-wu, Chen Ming-long, Yang Bing, Ju Wei-zhu, Zhang Feng-xiang, Gu Kai, Li Ming-fang, Gao Ke-jiang. [Clinical characteristics and long-term outcome of non-pulmonary vein foci ablation in patients with paroxysmal atrial fibrillation].. Zhonghua xin xue guan bing za zhi. 2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.