MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/dia.2023.0345

Медицинская библиотека · Diabetes technology & therapeutics · 2024

Feasibility and Validity of In-Home Self-Collected Capillary Blood Spot Screening for Type 1 Diabetes Risk.

Sing Anna B E, Naselli Gaetano, Huang Dexing, Watson Kelly, Colman Peter G, Harrison Leonard C, Wentworth John M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Aims: Self-collection of a blood sample for autoantibody testing has potential to facilitate screening for type 1 diabetes risk. We sought to determine the feasibility and acceptability of this approach and the performance of downstream antibody assays.

Methods

People living with type 1 diabetes and their family members (N = 97) provided paired capillary blood spot and serum samples collected, respectively, by themselves and a health worker. They provided feedback on the ease, convenience, and painfulness of blood spot collection. Islet antibodies were measured in blood spots by antibody detection by agglutination PCR (ADAP) or multiplex enzyme-linked immunoassay (ELISA), and in serum by radioimmunoassay (RIA) or ELISA.

Results

Using serum RIA and ELISA to define antibody status, 50 antibody-negative (Abneg) and 47 antibody-positive (Abpos) participants enrolled, of whom 43 and 47, respectively, returned testable blood spot samples. The majority indicated that self-collection was easier, more convenient, and less painful than formal venesection. The sensitivity and specificity for detection of Abpos by blood spot were, respectively, 85% and 98% for ADAP and 87% and 100% for multiplex ELISA. The specificities by ADAP for each of the four antigen specificities ranged from 98% to 100% and areas under the receiver operator curve from 0.841 to 0.986.

Conclusions

Self-collected blood spot sampling is preferred over venesection by research participants. ADAP and multiplex ELISA are highly specific assays for islet antibodies in blood spots with acceptable performance for use alone or in combination to facilitate screening for type 1 diabetes risk. Clinical Trial Registration number: ACTRN12620000510943.

Для цитирования: Sing Anna B E, Naselli Gaetano, Huang Dexing, Watson Kelly, Colman Peter G, Harrison Leonard C, Wentworth John M. Feasibility and Validity of In-Home Self-Collected Capillary Blood Spot Screening for Type 1 Diabetes Risk.. Diabetes technology & therapeutics. 2024. DOI: 10.1089/dia.2023.0345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.