MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/dia.2023.0261

Медицинская библиотека · Diabetes technology & therapeutics · 2023

Advanced Hybrid Closed-Loop System Achieves and Maintains Recommended Time in Range Levels for Up To 2 Years: Predictors of Best Efficacy.

Lepore Giuseppe, Borella Nicolò Diego, Castagna Giona, Ippolito Silvia, Bonfadini Silvia, Corsi Anna, Scaranna Cristiana, Dodesini Alessandro Roberto, Bellante Rosalia, Trevisan Roberto

СтатьяПеревод пока не подготовлен

Аннотация

Aim: To evaluate the long-term efficacy, up to 2 years, of an advanced hybrid closed-loop (AHCL) system and to assess predictors of best results of the therapy.

Methods

We retrospectively evaluated 296 adults with type 1 diabetes mellitus [mean age 42.8 ± 16.5 years, men 42.9%, duration of diabetes 22.5 ± 12.8 years, body mass index 24.9 ± 4.7 kg/m2, baseline glycated hemoglobin (HbA1c) 63.4 ± 12.2 mmol/mol (8.0 ± 1.1%) ] who used the MiniMed™ 780G system. Demographic and clinical data were recorded. Continuous glucose monitoring (CGM)-derived metrics and insulin requirement were analyzed from the 4 weeks before and from every quarter after the switch to the AHCL system.

Results

In the first quarter of AHCL treatment, all CGM metrics improved. Time in range (TIR) increased from 58.1 ± 17.5% to 70.3 ± 9.5% (P < 0.0001). The improvement lasted for up to 2 years of observation regardless of previous insulin therapies. Throughout the period of observation, 53.4% of participants achieved mean TIR >70%, 92.6% mean time below range <4%, and 46% mean glucose management indicator <53 mmol/mol (7.0%). At univariable logistic regression older age, lower baseline HbA1c and insulin requirement were associated with mean TIR >70%. At multivariable analysis, lower HbA1c remained independently associated with a better glycemic control. However, mean TIR increased more in participants with a higher baseline HbA1c.

Conclusions

Switching to an AHCL leads to a rapid improvement in glycemic control lasting for up to 24 months along with a low risk for hypoglycemia, confirming the safety of the system. Lower baseline HbA1c was the main predictor of better efficacy of therapy, although higher baseline HbA1c was associated with the greatest improvement in mean TIR.

Для цитирования: Lepore Giuseppe, Borella Nicolò Diego, Castagna Giona, Ippolito Silvia, Bonfadini Silvia, Corsi Anna, Scaranna Cristiana, Dodesini Alessandro Roberto, Bellante Rosalia, Trevisan Roberto. Advanced Hybrid Closed-Loop System Achieves and Maintains Recommended Time in Range Levels for Up To 2 Years: Predictors of Best Efficacy.. Diabetes technology & therapeutics. 2023. DOI: 10.1089/dia.2023.0261.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.