m+Medelevator.RU
← Поиск публикаций
Talanta · 2026

Ultrasensitive chemiluminescent detection of plasma Aβ1-40 based on soluble macromolecular signal amplification carrier.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guo Chaolin, Liu Meng, An Zhanfei, Li Shuaipeng, Cui Menglin, Nie Jianqi, Sun Yang, Bai Zhonghu

Аннотация

The research presents the development of an ultrasensitive chemiluminescent immunoassay (CLIA) for detecting the Alzheimer's disease (AD) biomarker amyloid-β (Aβ) 1-40 in plasma, utilizing novel monoclonal antibodies and an innovative soluble macromolecular signal amplification carrier, Ficoll400-Streptavidin (Ficoll400-SA) conjugates. The study successfully generated two high-affinity monoclonal antibodies (KD ≈ 10-10 M), designated 2F10 and 12H6, which are epitope-specific and target distinct N-terminal and C-terminal regions of Aβ1-40. These antibodies demonstrated exceptional specificity, exhibiting minimal cross-reactivity (<0.5%) with closely related isoforms like Aβ1-42. The Ficoll400-SA carrier, formed by conjugating multiple streptavidin molecules to the Ficoll400 backbone and further crosslinking, enabled substantial signal amplification by facilitating rapid, homogeneous reactions and high-density enzyme loading capacity. Optimization of assay conditions demonstrated a 13-fold signal enhancement compared to conventional streptavidin-horseradish peroxidase (SA-HRP) systems, achieving an ultra-low detection limit of 0.28 pg mL-1 and a broad dynamic range (0.54-1000 pg mL-1). The assay exhibited excellent precision (CV < 8%), robust stability under accelerated and onboard conditions, and outstanding specificity with negligible cross-reactivity. Clinical validation against a commercial Aβ1-40 assay using human plasma samples showed a remarkable correlation (Spearman's ρ = 0.99) and no systematic bias, confirming the assay's accuracy and translational potential. Overall, this integrated approach offers a robust, cost-effective, and ultrasensitive platform for Aβ1-40 quantification, advancing blood-based AD diagnostics and demonstrating the versatility of soluble macromolecular carriers in immunoassay signal amplification.

Предметные рубрики MeSH