MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr/19385909

Медицинская библиотека · The British journal of radiology · 2012

Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time.

Bernardi D, Ciatto S, Pellegrini M, Anesi V, Burlon S, Cauli E, Depaoli M, Larentis L, Malesani V, Targa L, Baldo P, Houssami N

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to supplement the paucity of information available on logistical aspects of the application of three-dimensional (3D) mammography in breast screening.

METHODS

We prospectively examined the effect on radiographers' and radiologists' workload of implementing 3D mammography in screening by comparing image acquisition time and screen-reading time for two-dimensional (2D) mammography with that of combined 2D+3D mammography. Radiologists' accuracy was also calculated.

RESULTS

Average acquisition time (measured from start of first-view breast positioning to compression release at completion of last view) for seven radiographers, based on 20 screening examinations, was longer for 2D+3D (4 min 3 s; range 3 min 53 s-4 min 18 s) than 2D mammography (3 min 13 s; range 3 min 0 s-3 min 26 s; p<0.01). Average radiologists' reading time per screening examination (three radiologists reading case-mix of 100 screens: 10 cancers, 90 controls) was longer for 2D+3D (77 s; range 60-90 s) than for 2D mammography (33 s; range 25-46 s; p<0.01). 2D+3D screen-reading was associated with detection of more cancers and with substantially fewer recalls than 2D mammography alone.

CONCLUSION

Relative to standard 2D mammography, combined 2D+3D mammography prolongs image acquisition time and screen-reading time (at initial implementation), and appears to be associated with improved screening accuracy.

ADVANCES IN KNOWLEDGE: These findings provide relevant information to guide larger trials of integrated 3D mammography (2D+3D) and its potential implementation into screening practice.

Для цитирования: Bernardi D, Ciatto S, Pellegrini M, Anesi V, Burlon S, Cauli E, Depaoli M, Larentis L, Malesani V, Targa L, Baldo P, Houssami N. Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time.. The British journal of radiology. 2012. DOI: 10.1259/bjr/19385909.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.