MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2011.12.013

Медицинская библиотека · European journal of radiology · 2012

Assessment of CAD-generated tumor volumes measured using MRI in breast cancers before and after neoadjuvant chemotherapy.

Takeda Kazuna, Kanao Shotaro, Okada Tomohisa, Kataoka Masako, Ueno Takayuki, Toi Masakazu, Ishiguro Hiroshi, Mikami Yoshiki, Togashi Kaori

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate inter-observer agreement and the predictive value of tumor size measurements using MRI for breast cancer under neoadjuvant chemotherapy (NAC) by comparing the measurements of the longest diameters (LD), total enhanced volumes (TEV) and washout volumes (WOV).

METHODS

Thirty-seven female breast cancer patients were prospectively enrolled from August 2008 to October 2010. Two of these patients had locally advanced disease. MRI examinations were acquired within 2 weeks before and after NAC. Interim scans were also conducted in 30 patients. Tumor resection was undertaken within 2 weeks after the cessation of NAC. MRI images were independently measured for LD, TEV and WOV by two experienced radiologists. Inter-observer agreement was evaluated using concordance correlation coefficients (CCCs). Tumor sizes after NAC were evaluated relative to their initial sizes for early prediction of a pathological complete response (pCR).

RESULTS

The CCCs were 0.93 (CI: 0.90-0.95) for LD, 0.98 (CI: 0.97-0.98) for TEV and 0.99 (CI: 0.991-0.996) for WOV. All measurements had high inter-observer agreement, but the CCCs were significantly increased in the aforementioned order (P<0.0001). WOV measured after the completion of chemotherapy had significant discriminating ability (P=0.0056) when evaluated using receiver operating characteristic analysis, and was found to be superior to LD (P=0.045). The average WOV size was significantly smaller in pCR cases than in non-pCR cases (P=0.016).

CONCLUSION

Computer-aided detection-generated tumor volumes had significantly higher inter-observer concordance than conventional LD measurements. WOV measurements had the highest concordance, and WOV could better predict pCR after NAC at smaller tumor sizes.

Для цитирования: Takeda Kazuna, Kanao Shotaro, Okada Tomohisa, Kataoka Masako, Ueno Takayuki, Toi Masakazu, Ishiguro Hiroshi, Mikami Yoshiki, Togashi Kaori. Assessment of CAD-generated tumor volumes measured using MRI in breast cancers before and after neoadjuvant chemotherapy.. European journal of radiology. 2012. DOI: 10.1016/j.ejrad.2011.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.