BACKGROUND

Ultrasonography (US) has been used as an important adjunct to mammography (MG), and automated breast US (ABUS) scanners were originally designed to effectively examine the breast in its entirety.

PURPOSE: To retrospectively assess the performance of radiologists in the detection of breast cancers, initially detected by hand-held ultrasound (HHUS), using 3D breast volume data obtained from a commercial ABUS system.

MATERIAL AND

METHODS

Bilateral whole breast US was performed using ABUS in 61 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses detected during screening HHUS. Fourteen cancers in 13 women and 48 normal breasts of 48 women with benign disease in the contralateral breast were selected. Three radiologists who had not performed the HHUS examinations independently reviewed the 3D ABUS data for any lesions that required recall for further evaluation. Sensitivities and false-positive rates were calculated.

RESULTS

The sensitivities of the three readers for cancer detection were 78.6% (11/14), 78.6%, and 57.1% (8/14), respectively, with false-positive rates of 20.8% (10/48), 12.5% (6/48) and 8.3% (4/48). Seven cancers were detected by all three readers, four cancers by two readers, and one cancer by one reader. Two invasive cancers were not detected by any reader.

CONCLUSION

Of HHUS-detected cancers, only 57.1-78.6% were identified with ABUS. A substantial level of experience and training is necessary to improve cancer detection by ABUS.

Для цитирования: Chang Jung Min, Moon Woo Kyung, Cho Nariya, Park Jeong Seon, Kim Seung Ja. Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound data.. Acta radiologica (Stockholm, Sweden : 1987). 2011. DOI: 10.1258/ar.2010.100179.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.