MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2011.01.074

Медицинская библиотека · European journal of radiology · 2011

Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS).

Chang Jung Min, Moon Woo Kyung, Cho Nariya, Park Jeong Seon, Kim Seung Ja

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To retrospectively evaluate the detection performance of benign and malignant breast masses using 3D volume data obtained by ABUS and to determine lesion variables which affect detectability.

METHODS

Between November and December of 2007, bilateral whole breast US images were obtained using ABUS in 67 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses. Twenty-four invasive ductal cancers in 23 breasts, 46 benign breast lesions in 44 breasts and 38 normal breasts were included. Three breast radiologists (experience range, 8-16 years) who did not perform the examinations and were blinded to the histology independently reviewed the ABUS data of the 105 breasts to detect suspicious solid masses with pathology as the standard of reference. Sensitivity and specificity in detecting benign and malignant masses were calculated, and lesion characteristics affecting detectability were analyzed.

RESULTS

Sensitivities for benign and malignant mass detections were 65.2% (30/46), 95.8% (23/24) for reader 1 (p=0.007), 66.7% (31/46), 87.5% (21/24) for reader 2 (p=0.087), and 56.3% (24/46), 91.7% (22/24), for reader 3 (p=0.001), respectively. Logistic analysis showed that mass size (odds ratio, 95% CI; 1.12, 1.02-1.24), surrounding tissue changes (odds ratio, 95% CI; 0.11, 0.02-0.47), and shape of the mass (odds ratio, 95% CI; 3.12, 1.02-9.55) were the variables associated with detectability at ABUS.

CONCLUSION

In reader studies using ABUS data, significantly higher sensitivity was noted for malignant breast masses than for benign masses.

Для цитирования: Chang Jung Min, Moon Woo Kyung, Cho Nariya, Park Jeong Seon, Kim Seung Ja. Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS).. European journal of radiology. 2011. DOI: 10.1016/j.ejrad.2011.01.074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.