MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15910199251359359

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025

The impact of microcatheter-to-vessel size ratio on distal embolization during mechanical thrombectomy-an in vitro quantitative study: Comparative study of different microcatheter sizes in different neurovascular models.

Tiberi Riccardo, Li Jiahui, Jablonska Magda, Vargas Joan Daniel, Tomasello Alejandro, Ribo Marc

СтатьяПеревод пока не подготовлен

Аннотация

Background and purposeMechanical thrombectomy (MT) is the gold standard for treating large vessel occlusions. Given the variability in vessel anatomy among patients and the sometimes arbitrary selection of devices by neurointerventionalists, the choice of microcatheter size requires thorough evaluation. We aim to evaluate the impact of device-to-vessel size ratio on periprocedural distal embolization.Materials and methodsFragment-prone clot analogs (length = 9.86±0.07 mm) were used to embolize three different vessels (lumen = 2.0, 2.5, 3.5 mm) in a three-dimensional-printed neurovascular model. Three different microcatheter sizes (0.017″, 0.021″, 0.027″) were used to cross the lesion and subsequently, migrated clot fragments were collected in an outflow filter for image analysis. Experiments were conducted both with and without a microguidewire. A total of 180 experiments were performed: 60 for each M1 segment of middle cerebral artery size, including 20 for each microcatheter-10 with J-shaped microguidewire and 10 without.ResultsAcross all vessels, the 0.027″ microcatheter caused more distal embolizations compared to 0.017″ (p = 0.04) and 0.021″ (p = 0.01). In the 2 mm M1-MCA, 0.017″ microcatheter reduced emboli compared to 0.021″ (p = 0.062) and 0.027″ (p = 0.017). Procedures in the 2 mm vessel are significantly more prone to embolization compared to larger M1 segments (p < 0.05). Microcatheter-to-vessel ratio ≥0.38 significantly increases risk of distal embolization. The use of microguidewire in the procedures did not have any impact on distal embolization (p = 0.871).ConclusionA larger device-to-vessel size ratio induces an increase in distal embolization. Neurointerventionalists should carefully consider vessel anatomy for appropriate microcatheter size selection to minimize the risk of distal embolization.

Для цитирования: Tiberi Riccardo, Li Jiahui, Jablonska Magda, Vargas Joan Daniel, Tomasello Alejandro, Ribo Marc. The impact of microcatheter-to-vessel size ratio on distal embolization during mechanical thrombectomy-an in vitro quantitative study: Comparative study of different microcatheter sizes in different neurovascular models.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2025. DOI: 10.1177/15910199251359359.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.