Double cycling with breath-stacking during partial support ventilation in ARDS: Just a feature of natural variability?

Brito Roberto, Morais Caio C A, Arellano Daniel H, Gajardo Abraham I J, Bruhn Alejandro, Brochard Laurent J, Amato Marcelo B P, Cornejo Rodrigo A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Double cycling with breath-stacking (DC/BS) during controlled mechanical ventilation is considered potentially injurious, reflecting a high respiratory drive. During partial ventilatory support, its occurrence might be attributable to physiological variability of breathing patterns, reflecting the response of the mode without carrying specific risks.

METHODS

This secondary analysis of a crossover study evaluated DC/BS events in hypoxemic patients resuming spontaneous breathing in cross-over under neurally adjusted ventilatory assist (NAVA), proportional assist ventilation (PAV +), and pressure support ventilation (PSV). DC/BS was defined as two inspiratory cycles with incomplete exhalation. Measurements included electrical impedance signal, airway pressure, esophageal and gastric pressures, and flow. Breathing variability, dynamic compliance (CLdyn), and end-expiratory lung impedance (EELI) were analyzed.

RESULTS

Twenty patients under assisted breathing, with a median of 9 [5-14] days on mechanical ventilation, were included. DC/BS was attributed to either a single (42%) or two apparent consecutive inspiratory efforts (58%). The median [IQR] incidence of DC/BS was low: 0.6 [0.1-2.6] % in NAVA, 0.0 [0.0-0.4] % in PAV + , and 0.1 [0.0-0.4] % in PSV (p = 0.06). DC/BS events were associated with patient's coefficient of variability for tidal volume (p = 0.014) and respiratory rate (p = 0.011). DC/BS breaths exhibited higher tidal volume, muscular pressure and regional stretch compared to regular breaths. Post-DC/BS cycles frequently exhibited improved EELI and CLdyn, with no evidence of expiratory muscle activation in 63% of cases.

CONCLUSIONS

DC/BS events during partial ventilatory support were infrequent and linked to breathing variability. Their frequency and physiological effects on lung compliance and EELI resemble spontaneous sighs and may not be considered a priori as harmful.

Для цитирования: Brito Roberto, Morais Caio C A, Arellano Daniel H, Gajardo Abraham I J, Bruhn Alejandro, Brochard Laurent J, Amato Marcelo B P, Cornejo Rodrigo A. Double cycling with breath-stacking during partial support ventilation in ARDS: Just a feature of natural variability?. Critical care (London, England). 2025. DOI: 10.1186/s13054-025-05260-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.