MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00234-010-0655-z

Медицинская библиотека · Neuroradiology · 2010

Accuracy of 3 T MR angioraphy in vertebral artery stenosis and coincidence with other cerebrovascular stenoses.

Choi Hyun Seok, Kim Dong Ik, Kim Dong Joon, Kim Jinna, Kim Eun Soo, Lee Seung-Koo

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Ostium of vertebral artery (VA) is a common site of pseudostenosis on contrast-enhanced MR angiography (CE-MRA). The purpose of this study was to determine the diagnostic accuracy of CE-MRA at 3 T in the evaluation of ostial stenosis of VA and to find associated coincidental stenoses using logistic regression analysis.

METHODS

One hundred and thirty-five VA ostial regions from 72 patients who received CE-MRA of neck vessels, intracranial time of flight (TOF) MRA, and digital subtraction angiography (DSA) were retrospectively reviewed. The sensitivity and specificity of the CE-MRA in detection of ostial stenosis were calculated with reference standard of DSA. Ostial stenosis on MRA was correlated with coincidental lesions in intracranial and cervical arteries by logistic regression analysis.

RESULTS

The sensitivity and specificity of the CE-MRA were 100% and 80.4% for detection of significant stenosis. In case of significant stenoses, CE-MRA showed a tendency of overestimation with a false-positive rate of 52.5%. Logistic regression analysis showed that the stenoses of middle cerebral artery (MCA) on TOF MRA was associated with significant stenoses of VA ostia (OR = 5.84, 95% confidence intervals 1.41-24.17).

CONCLUSION

CE-MRA is sensitive in detection of VA ostial stenosis although it has high false-positive rate. True positive ostial stenosis should be considered in cases of coincidental stenoses of MCA on TOF MRA.

Для цитирования: Choi Hyun Seok, Kim Dong Ik, Kim Dong Joon, Kim Jinna, Kim Eun Soo, Lee Seung-Koo. Accuracy of 3 T MR angioraphy in vertebral artery stenosis and coincidence with other cerebrovascular stenoses.. Neuroradiology. 2010. DOI: 10.1007/s00234-010-0655-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.