DOI 10.1007/s00234-009-0589-5

Медицинская библиотека · Neuroradiology · 2009

Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography.

Saba Luca, Sanfilippo Roberto, Montisci Roberto, Mallarini Giorgio

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT).

METHODS

Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value +/- standard deviation and were compared using the Mann-Whitney U test. A p value <0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US.

RESULTS

CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 +/- 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377.

CONCLUSIONS

Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT.

Для цитирования: Saba Luca, Sanfilippo Roberto, Montisci Roberto, Mallarini Giorgio. Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography.. Neuroradiology. 2009. DOI: 10.1007/s00234-009-0589-5.