MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15910199231226285

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024

Single-center outcomes of Onyx Frontier™ and Resolute Onyx™ drug-eluting balloon-mounted stents for rescue stenting for acute large vessel occlusion.

Mehta Shyle H, White Timothy G, Shah Kevin A, Lynch Daniel G, Werner Cassidy D, Teron Ina, Link Thomas, Patsalides Athos, Woo Henry H

СтатьяПеревод пока не подготовлен

Аннотация

BackgroundIn cases where mechanical thrombectomy (MT) fails, rescue stenting may be necessary to achieve reperfusion; however, the lack of standardized techniques or devices poses a challenge. This series aims to present our early experience with the Onyx Frontier™ and Resolute Onyx™ balloon-mounted drug-eluting stents for rescue stenting.MethodsA retrospective chart review was performed of all patients who underwent rescue stenting, in the setting of failed MT, using Onyx Frontier™ or Resolute Onyx™ stents at a single institution. Technical details, procedural complications, and patient outcomes were recorded for each case.ResultsTwenty-two Onyx Frontier™ and Resolute Onyx™ stents were deployed in 18 patients undergoing rescue stenting. Stent locations included the middle cerebral artery (36.4%), internal carotid artery (18.2%), vertebral artery (22.7%), and basilar artery (22.7%). The average National Institutes of Health Stroke Scale score before MT was 13.8 (range 0-31). The median initial modified Rankin Scale (mRS) score was zero, while the median mRS score at follow-up was three. Successful reperfusion, as assessed by TICI scores, was achieved in 43.8% of patients for TICI 3, 43.8% for TICI 2C, and 12.5% for TICI 2B. Post-revascularization, 16.7% of patients experienced hemorrhage, of which one patient (5.6%) had symptomatic hemorrhage.ConclusionsOnyx Frontier™ and Resolute Onyx™ stents are well suited for rescue stenting in cases of failed MT. These balloon-mounted drug-eluting stents exhibit excellent navigability, rendering them appropriate for rescue revascularization procedures. Our findings demonstrate that these stents confer a high degree of technical success.

Для цитирования: Mehta Shyle H, White Timothy G, Shah Kevin A, Lynch Daniel G, Werner Cassidy D, Teron Ina, Link Thomas, Patsalides Athos, Woo Henry H. Single-center outcomes of Onyx Frontier™ and Resolute Onyx™ drug-eluting balloon-mounted stents for rescue stenting for acute large vessel occlusion.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2024. DOI: 10.1177/15910199231226285.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.