Аннотация

OBJECTIVE

Waist circumference (WC) is a widely accepted anthropometric parameter of central obesity. We investigated a fully automated body segmentation algorithm for measuring WC on abdominal computed tomography (CT) in comparison to manual WC measurements (WC-manual) and evaluated the performance of CT-measured WC for identifying overweight/obesity.

MATERIALS AND

METHODS

This retrospective study included consecutive adults who underwent both abdominal CT scans and manual WC measurements at a health check-up between January 2013 and November 2019. Mid-waist WCs were automatically measured on noncontrast axial CT images using a deep learning-based body segmentation algorithm. The associations between CT-measured WC and WC-manual was assessed by Pearson correlation analysis and their agreement was assessed through Bland-Altman analysis. The performance of these WC measurements for identifying overweight/obesity (i.e., body mass index [BMI] ≥25 kg/m2) was evaluated using receiver operating characteristics (ROC) curve analysis.

RESULTS

Among 763 subjects whose abdominal CT scans were analyzed using a fully automated body segmentation algorithm, CT-measured WCs were successfully obtained in 757 adults (326 women; mean age, 54.3 years; 64 women and 182 men with overweight/obesity). CT-measured WC was strongly correlated with WC-manual (r = 0.919, p < 0.001), and showed a mean difference of 6.1 cm with limits of agreement between -1.8 cm and 14.0 cm in comparison to WC-manual. For identifying overweight/obesity, CT-measured WC showed excellent performance, with areas under the ROC curve (AUCs) of 0.960 (95% CI, 0.933-0.979) in women and 0.909 (95% CI, 0.878-0.935) in men, which were comparable to WC-manual (AUCs of 0.965 [95% CI, 0.938-0.982] and 0.916 [95% CI, 0.886-0.941]; p = 0.735 and 0.437, respectively).

CONCLUSION

CT-measured WC using a fully automated body segmentation algorithm was closely correlated with manually-measured WC. While radiation issue may limit its general use, it can serve as an adjunctive output of abdominal CT scans to identify overweight/obesity.

Для цитирования: Joo Ijin, Kwak Min-Sun, Park Dae Hyun, Yoon Soon Ho. Fully automated waist circumference measurement on abdominal CT: Comparison with manual measurements and potential value for identifying overweight and obesity as an adjunct output of CT scan.. PloS one. 2021. DOI: 10.1371/journal.pone.0254704.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.