MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0399-8320(06)73376-0

Медицинская библиотека · Gastroenterologie clinique et biologique · 2006

Perendoscopic variceal pressure measurement: a reliable estimation of portal pressure in patients with cirrhosis?

Spahr Laurent, Giostra Emile, Morard Isabelle, Mentha Gilles, Hadengue Antoine

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

In patients with cirrhosis, the hepatic venous pressure gradient (HVPG) is the reference method for the assessment of portal hypertension (PHT). Variceal pressure (VP) may be measured at endoscopy, but its relationship to the HVPG remains controversial. The aim of the study was to retrospectively compare HVPG and VP values obtained in a cohort of patients with cirrhosis and PHT.

METHODS

Within 8 days (range: 6-10 days), 64 patients in a stable condition with biopsy-proven cirrhosis [alcoholic: 47; other 17; mean age: 56.5 yrs (35-70); mean Child-Pugh's score: 9.4 +/- 1.9; ascites: 37/64; previous variceal bleeding (="bleeders"): 24/64) and oesophageal varices (grade 2: 49; grade 3: 15)] underwent both measurement of the HVPG during transjugular liver biopsy and VP at endoscopy using a "home made" pressure sensitive gauge in the absence of needle puncture of the varix. Alcoholic hepatitis was present in 28 patients with alcoholic cirrhosis.

RESULTS

The pressure sensitive gauge was well tolerated. The mean HVPG and VP values were 18.5 +/- 3.4 mmHg and 19 +/- 3.7 mmHg, respectively. A significant difference was observed between "bleeders" (n=24) and non "bleeders" (n=40) in terms of VP values (21.4 +/- 3.3 vs 17.2 +/- 3.2 mmHg, P<0.001), but not for HVPG values (19.4 +/- 4.1 vs 17.9 +/- 2.8 mmHg, P=0.075). A positive correlation was observed between VP and HVPG values (r=0.62, P<0.0001).

CONCLUSIONS

In this group of patients with cirrhosis and oesophageal varices, a "home-made" pressure sensitive gauge allowed a non invasive perendoscopic measurement of VP. The positive correlation between VP and HVPG values suggests that measurement of VP may be a reliable estimate of portal pressure in these patients.

Для цитирования: Spahr Laurent, Giostra Emile, Morard Isabelle, Mentha Gilles, Hadengue Antoine. Perendoscopic variceal pressure measurement: a reliable estimation of portal pressure in patients with cirrhosis?. Gastroenterologie clinique et biologique. 2006. DOI: 10.1016/s0399-8320(06)73376-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.