MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/cc4985

Медицинская библиотека · Critical care (London, England) · 2006

Effect of the molecular adsorbent recirculating system and Prometheus devices on systemic haemodynamics and vasoactive agents in patients with acute-on-chronic alcoholic liver failure.

Laleman Wim, Wilmer Alexander, Evenepoel Pieter, Elst Ingrid Vander, Zeegers Marcel, Zaman Zahur, Verslype Chris, Fevery Johan, Nevens Frederik

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Patients with acute-on-chronic liver failure show an aggravated hyperdynamic circulation. We evaluated, in a controlled manner, potential changes in systemic haemodynamics induced by the molecular adsorbent recirculating system (MARS) and the Prometheus system liver detoxification devices in a group of patients with acute-on-chronic liver failure.

METHODS

Eighteen patients (51.2 +/- 2.3 years old; Child-Pugh score, 12.5 +/- 0.2; Maddrey score, 63.1 +/- 5.0; hepatic venous pressure gradient, 17.6 +/- 0.9 mmHg) with biopsy-proven alcoholic cirrhosis and superimposed alcoholic hepatitis were either treated with standard medical therapy (SMT) combined with MARS (n = 6) or Prometheus (n = 6) or were treated with SMT alone (n = 6) on three consecutive days (6 hours/session). Liver tests, systemic haemodynamics and vasoactive substances were determined before and after each session.

RESULTS

Groups were comparable for baseline haemodynamics and levels of vasoactive substances. Both MARS and Prometheus decreased serum bilirubin levels (P < 0.005 versus SMT), the Prometheus device being more effective than MARS (P = 0.002). Only MARS showed significant improvement in the mean arterial pressure (Deltachange, +9 +/- 2.4 mmHg versus -0.3 +/- 2.4 mmHg with Prometheus and -5.2 +/- 2.1 mmHg with SMT, P < 0.05) and in the systemic vascular resistance index (Deltachange, +131.5 +/- 46.2 dyne x s/cm5/m2 versus -92.8 +/- 85.2 dyne x s/cm5/m2 with Prometheus and -30.7 +/- 32.5 dyne x s/cm5/m2 with SMT; P < 0.05), while the cardiac index and central filling remained constant. This circulatory improvement in the MARS group was paralleled by a decrease in plasma renin activity (P < 0.05), aldosterone (P < 0.03), norepinephrine (P < 0.05), vasopressin (P = 0.005) and nitrate/nitrite levels (P < 0.02).

CONCLUSION

The MARS device, and not the Prometheus device, significantly attenuates the hyperdynamic circulation in acute-on-chronic liver failure, presumably by a difference in removal rate of certain vasoactive substances. These findings suggest conspicuous conceptual differences among the albumin dialysis devices.

Для цитирования: Laleman Wim, Wilmer Alexander, Evenepoel Pieter, Elst Ingrid Vander, Zeegers Marcel, Zaman Zahur, Verslype Chris, Fevery Johan, Nevens Frederik. Effect of the molecular adsorbent recirculating system and Prometheus devices on systemic haemodynamics and vasoactive agents in patients with acute-on-chronic alcoholic liver failure.. Critical care (London, England). 2006. DOI: 10.1186/cc4985.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.