MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cardfail.2025.02.013

Медицинская библиотека · Journal of cardiac failure · 2025

Pulmonary Congestion on Lung Ultrasound in Ambulatory Patients With Heart Failure With Preserved Ejection Fraction.

Platz Elke, McDowell Kirsty, Gupta Deepak K, Claggett Brian, Brennan Alice, Charles Lawrence J, Cunningham Jonathan W, Dixon Debra D, Docherty Kieran F, Jering Karola, Oggs Rashundra, Palacios Julia, Schwede Madeleine, Ravi Katherine Scovner, Sukumar Shivasankar M, Wassenaar Jean W, Lewis Eldrin F, McMurray John J V, Campbell Ross T

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Early detection of pulmonary congestion among ambulatory patients with heart failure with preserved ejection fraction (HFpEF) is critical to optimize decongestive therapy before overt decompensation, yet traditional tools are insensitive. We sought to examine the prevalence of B-lines, an ultrasound measure of pulmonary congestion, and their clinical and imaging correlates in patients with HFpEF.

METHODS AND

RESULTS

In a prospective, multisite observational study, using a pocket ultrasound device, 8-zone lung ultrasound examination was performed in outpatients with HFpEF, left ventricular ejection fraction (LVEF) of ≥45% and New York Heart Association functional class II through IV. B-lines and cardiac structure and function from echocardiograms were quantified off-line in core laboratories, blinded to clinical findings. Among 415 participants (mean age 74 years, 52% women, 51% obese, median N-terminal pro-B-type natriuretic peptide [NT-proBNP] 744 pg/mL) B-lines were detectable in 78% of patients ranging from 0 to 36 (median 3, interquartile range 1-6). There was a linear association between B-line count and log-transformed NT-proBNP (P < .001). Among patients in the highest tertile of B-lines, 76% had no crackles on auscultation, and 50% did not have elevated NT-proBNP levels. A higher B-line count was associated with larger sizes of cardiac chambers, greater left ventricular mass, higher filling pressures (E/e'), tricuspid regurgitant velocity, and inferior vena cava size, and worse right ventricular systolic function (P for trend < .05 for all), but not left ventricular ejection fraction.

CONCLUSIONS

Among ambulatory patients with HFpEF, lung ultrasound-detected B-lines were common, associated with NT-proBNP levels and clinically important echocardiographic features, and identified pulmonary congestion that was not always evident by auscultation.

Для цитирования: Platz Elke, McDowell Kirsty, Gupta Deepak K, Claggett Brian, Brennan Alice, Charles Lawrence J, Cunningham Jonathan W, Dixon Debra D, Docherty Kieran F, Jering Karola, Oggs Rashundra, Palacios Julia, Schwede Madeleine, Ravi Katherine Scovner, Sukumar Shivasankar M, Wassenaar Jean W, Lewis Eldrin F, McMurray John J V, Campbell Ross T. Pulmonary Congestion on Lung Ultrasound in Ambulatory Patients With Heart Failure With Preserved Ejection Fraction.. Journal of cardiac failure. 2025. DOI: 10.1016/j.cardfail.2025.02.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.