Five-year results of the STABLE II study for the endovascular treatment of complicated, acute type B aortic dissection with a composite device design.

Lombardi Joseph V, Gleason Thomas G, Panneton Jean M, Starnes Benjamin W, Dake Michael D, Haulon Stephan, Mossop Peter J, Segbefia Edem, Bharadwaj Priya, STABLE II investigators

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To provide the 5-year outcomes of the use of a composite device (proximal covered stent graft + distal bare stent) for endovascular repair of patients with acute, type B aortic dissection complicated by aortic rupture and/or malperfusion.

METHODS

Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE) II was a prospective, multicenter study of the Zenith Dissection Endovascular System (William Cook Europe). Patients were enrolled between August 2012 and January 2015 at sites in the United States and Japan. Five-year follow-up was completed by January 2020.

RESULTS

In total, 73 patients (mean age: 60.7 ± 10.9 years; 65.8% male) with acute type B dissection complicated by malperfusion (72.6%), rupture (21.9%), or both (5.5%) were enrolled. Patients were treated with either a composite device (79.5%) or the proximal stent graft alone (no distal bare stent, 20.5%). Dissections were more extensive in patients who received the composite device (408.9 ± 121.3 mm) than in patients who did not receive a bare stent (315.9 ± 100.1 mm). The mean follow-up was 1209.4 ± 754.6 days. Freedom from all-cause mortality was 80.3% ± 4.7% at 1 year and 68.9% ± 7.3% at 5 years. Freedom from dissection-related mortality remained at 97.1% ± 2.1% from 1-year through 5-year follow-up. Within the stent-graft region, the rate of either complete thrombosis or elimination of the false lumen increased over time (82.1% of all patients at 5 years vs 55.7% at first postprocedure computed tomography), with a higher rate at 5 years in patients who received the composite device (90.5%) compared with patients without the bare stent (57.1%). Throughout the follow-up, overall true lumen diameter increased within the stent-graft region, and overall false lumen diameter decreased. At 5 years, 20.7% of patients experienced a decrease in maximum transaortic diameter within the stent-graft region, 17.2% experienced an increase, and 62.1% experienced no change. Distal to the treated segment (but within the dissected aorta), 23.1% of patients experience no change in transaortic diameter at 5 years; a bare stent was deployed in all these patients at the procedure. Five-year freedom from all secondary intervention was 70.7% ± 7.2%.

CONCLUSIONS

These 5-year outcomes indicate a low rate of dissection-related mortality for the Zenith Dissection Endovascular System in the treatment of patients with acute, complicated type B aortic dissection. Further, these data suggest a positive influence of composite device use on false lumen thrombosis. Continuous monitoring for distal aortic growth is necessary in all patients.

Для цитирования: Lombardi Joseph V, Gleason Thomas G, Panneton Jean M, Starnes Benjamin W, Dake Michael D, Haulon Stephan, Mossop Peter J, Segbefia Edem, Bharadwaj Priya, STABLE II investigators. Five-year results of the STABLE II study for the endovascular treatment of complicated, acute type B aortic dissection with a composite device design.. Journal of vascular surgery. 2022. DOI: 10.1016/j.jvs.2022.06.092.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.