DOI 10.1016/j.ijbiomac.2024.134178

Медицинская библиотека · International journal of biological macromolecules · 2024

Enhanced modified poly-tyrosine voltammetric sensor for the quantification detection of salivary pepsin.

El-Kamel Renad S, Fekry Amany M

СтатьяПеревод пока не подготовлен

Аннотация

Pepsin as an aspartic acid protease member and one of the three foremost proteolytic enzymes in the digestive system is essential to be detected. An electrochemically polymerized tyrosine film on carbon paste electrode (pTyr/CPE) has been synthesized by electro-polymerization donating an affordable electrochemical sensor to sense salivary pepsin as a diagnostic technique for gastroesophageal reflux disease (GRD) due to saliva collection is non-invasive and relatively comfortable. The pTyr/CPE was applied for Voltammetric sensing of pepsin and its quantification in phosphate buffer solution of pH 2.0 (PBS). Scanning electron microscopy (SEM) was conducted to learn the surface morphology. Cyclic voltammetry (CV), differential pulse voltammetry (DPVs), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) were developed to realize the electrocatalytic activity of the sensor. The pTyr/CPE proceeded as a sensitive detector to pepsin with two linear ranges from 1 to 20 & 20 to 100 ng/mL donating two limits of detection as 0.5 & 0.09 ng/mL, respectively, and high selectivity toward pepsin, as well as stability and fast response of 1.5 s. Consequently, it is guessed that the pTyr/CPE sensor could be supportive for the initial diagnosis of GRD through the detection of pepsin in saliva. Finally, we quantified the pepsin levels in saliva samples of LPR patients (n = 2), showing that the results were agreeable with those from the electrochemical sensor.

Для цитирования: El-Kamel Renad S, Fekry Amany M. Enhanced modified poly-tyrosine voltammetric sensor for the quantification detection of salivary pepsin.. International journal of biological macromolecules. 2024. DOI: 10.1016/j.ijbiomac.2024.134178.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.