MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/nmo.14803

Медицинская библиотека · Neurogastroenterology and motility · 2024

Four-dimensional impedance manometry volume metrics for predicting abnormal bolus retention.

Pitisuttithum Panyavee, Goudie Eric, Araujo Isis K, Halder Sourav, Carlson Dustin A, Pandolfino John E, Kou Wenjun

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The objective measurement for esophageal bolus volume and bolus clearance could classify abnormal high-resolution manometry (HRM) beyond the current Chicago classification. We aimed to compare the novel four-dimensional impedance manometry (4D HRM) volume metrics with timed barium esophagram (TBE).

METHODS

Adults with esophageal symptoms undergoing HRM and TBE were included. A custom-built program for 4D HRM analysis measured esophageal luminal cross-sectional area (CSA) from impedance and subsequently derived esophageal bolus volume and clearance. 4D HRM volume metrics included pre-swallow residual volume, maximal volume, retention volume, and clearance ratio defined as 1.0-retention volume divided by the maximal volume. An abnormal TBE was defined as a column height >5 cm at 1 min or 5 min.

KEY

RESULTS

A total of 95 patients (normal motility: 33%; ineffective esophageal motility: 12%; absent contractility: 10%; esophagogastric junction outflow obstruction: 30%; type I achalasia: 5%; type II achalasia: 12%) were categorized into normal TBE (58%), abnormal TBE at 1 min (17%), and abnormal TBE at 5 min (25%). The AUROC demonstrated that, among all 4D HRM volume metrics, the clearance ratio had the best performance in predicting abnormal TBE at 5 min (AUROC, 95% confidence interval: 0.89, 0.82-0.96), and exhibited a strong negative correlation with TBE at 5 min (r = -0.65; p < 0.001).

CONCLUSIONS & INFERENCES: Novel 4D HRM volume metrics provide objective measurement of esophageal bolus volume and bolus clearance. The clearance ratio has a strong correlation with TBE and could potentially serve as a substitute for TBE to measure esophageal retention.

Для цитирования: Pitisuttithum Panyavee, Goudie Eric, Araujo Isis K, Halder Sourav, Carlson Dustin A, Pandolfino John E, Kou Wenjun. Four-dimensional impedance manometry volume metrics for predicting abnormal bolus retention.. Neurogastroenterology and motility. 2024. DOI: 10.1111/nmo.14803.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.