Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2019
IN.PACT SFA Clinical Study Using the IN.PACT Admiral Drug-Coated Balloon in a Chinese Patient Population.
Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chen Zhong, Guo Wei, Jiang Weiliang, Wang Feng, Fu Weiguo, Zou Yinghua, Deckers Stefanie, Li Pei, Popma Jeffrey J, Jaff Michael R
Аннотация
Purpose: To confirm the safety and effectiveness of the IN.PACT Admiral drug-coated balloon (DCB) as a treatment for de novo and native artery restenotic lesions in the superficial femoral artery (SFA) and/or proximal popliteal artery in Chinese subjects. Materials and Methods: IN.PACT SFA China (ClinicalTrials.gov identifier NCT02118532) was a single-arm, independently adjudicated, prospective, premarket study that enrolled 143 subjects (mean age 66.8±7.7 years; 107 men) at 15 centers. The predominant risk factors were hypertension (104, 72.7%) and diabetes mellitus (66, 46.2%). The majority of subjects were classified as Rutherford category 2 or 3 [69 (48.3%) and 55 (38.5%), respectively]; 19 (13.3%) subjects had critical limb ischemia (Rutherford category 4). The mean lesion length was 10.4±6.51 cm; more than half of the lesions (75, 52.4%) were chronic total occlusions. Calcification was found in 66 (46.2%) lesions. Outcomes at 12 months were compared with DCB safety and effectiveness performance goals derived from the literature. The 30-day primary safety outcome was a composite of freedom from device- and procedure-related mortality, major target limb amputation, and clinically-driven target lesion revascularization (CD-TLR). Results: The primary safety outcome was 99.3% at 30 days. Follow-up compliance at 12 months was 92.6%. Estimated 1-year primary patency using Kaplan-Meier analysis was 90.9% and freedom from CD-TLR was 97.1%. The rate of CD-TLR at 12 months was 2.9%. The Rutherford category status improved significantly (p<0.001) between baseline and 12 months. Conclusion: Results from IN.PACT SFA China demonstrated high rates of patency and low rates of CD-TLR in Chinese subjects through 12 months despite patient and lesion complexity. These data are consistent with the results of other IN.PACT DCB trials.
Предметные рубрики MeSH
AgedAmputation, SurgicalAngioplasty, BalloonCardiovascular AgentsChinaCoated Materials, BiocompatibleConstriction, PathologicFemaleFemoral ArteryHumansLimb SalvageMalePaclitaxelPeripheral Arterial DiseasePopliteal ArteryProgression-Free SurvivalProspective StudiesRecurrenceRisk FactorsTime FactorsVascular Access DevicesVascular Patency