MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2019.05.055

Медицинская библиотека · International journal of cardiology · 2019

Intentional combination of ProGlide and Angio-Seal for femoral access haemostasis in transcatheter aortic valve replacement.

Ko Tsung-Yu, Kao Hsien-Li, Liu Ying-Ju, Yeh Chih-Fan, Huang Ching-Chang, Chen Ying-Hsien, Hung Chi-Sheng, Chan Chih-Yang, Lin Lung-Chun, Chen Yih-Sharng, Lin Mao-Shin

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To describe and evaluate the intentional combination of Angio-Seal (AS) and Perclose ProGlide (PP) in achieving haemostasis in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR).

METHODS

This study cohort was divided into two groups: dual PP versus one AS with one PP (AS + PP) used for common femoral artery haemostasis. The baseline, procedural characteristics and all outcomes (defined according toVARC-2 criteria) were prospectively collected and retrospectively compared.

RESULTS

Overall, a total of 151 consecutive patients (68 men; 80.9 ± 7.3 years old) were evaluated. Of these, 51 patients (33.8%) underwent TAVR using the dual PP, and 100 (66.2%) using one AS with one PP. There were no significant differences in the baseline characteristics of both patient groups, except higher incidence of chronic pulmonary disease in dual PP group (21.6% vs 7%, P = 0.009). Patients in AS + PP group had lower rate of arterial stricture (21.6% vs 8%, P = 0.017), arterial dissection (13.7% vs 4.0%), requiring endovascular intervention for puncture site issues (21.6% vs 9.0%, P = 0.031). Less procedural time (139.8 ± 36.9vs97.9 ± 31.4 min, P < 0.001) & contrast medium consumption (223.9 ± 88.3vs174.1 ± 49.7 ml, P < 0.001) were also observed in AS+PP group. There were no statistically significant differences between 2 groups in regards of closure device failure, major and minor vascular complications, nor major and minor bleeding.

CONCLUSIONS

Intentional combination of one PP and one AS for femoral access haemostasis in patients undergoing TAVR is feasible and safe, with low risk of vascular and bleeding complications.

Для цитирования: Ko Tsung-Yu, Kao Hsien-Li, Liu Ying-Ju, Yeh Chih-Fan, Huang Ching-Chang, Chen Ying-Hsien, Hung Chi-Sheng, Chan Chih-Yang, Lin Lung-Chun, Chen Yih-Sharng, Lin Mao-Shin. Intentional combination of ProGlide and Angio-Seal for femoral access haemostasis in transcatheter aortic valve replacement.. International journal of cardiology. 2019. DOI: 10.1016/j.ijcard.2019.05.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.