A novel CT-guided technique using medical adhesive for localization of small pulmonary ground-glass nodules and mixed ground-glass nodules (≤20 mm) before video-assisted thoracoscopic surgery.

Tao Gu, Jingying Yu, Tan Guo, Xiaotao Deng, Min Chen

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We aimed to evaluate the success rate and complication occurrence of CT-guided localization of small pure ground-glass nodules (pGGNs) and mixed ground-glass nodules (mGGNs) with medical adhesive injection before video-assisted thoracoscopic surgery (VATS).

METHODS

From March 2015 to May 2017, 41 patients with 44 small pGGNs and mGGNs underwent CT-guided percutaneous localization with medical adhesive prior to wedge resection by VATS.

RESULTS

Localization with medical adhesive was successful in all patients (100%). The nodules (13 pGGNs, 31 mGGNs) had a mean maximal long-axis diameter of 9±4 mm and a mean distance of 10±7 mm from the most superficial edge of the nodule to the visceral pleura. The localization time was 16±8 minutes. There was a moderate inverse relationship between localization time and the nodule diameter (r= -0.42, P = 0.005). Thirty-three nodules with primary lung cancer were pathologically confirmed. There were 3 cases of pneumothorax (7%), 3 cases of parenchyma hemorrhage (7%) and 2 cases of irritable cough (5%), respectively. No conversion to thoracotomy was necessary in any patient.

CONCLUSION

CT-guided percutaneous localization with medical adhesive can label small pGGNs and mGGNs prior to VATS, with high success and low complication rates.

Для цитирования: Tao Gu, Jingying Yu, Tan Guo, Xiaotao Deng, Min Chen. A novel CT-guided technique using medical adhesive for localization of small pulmonary ground-glass nodules and mixed ground-glass nodules (≤20 mm) before video-assisted thoracoscopic surgery.. Diagnostic and interventional radiology (Ankara, Turkey). 2018. DOI: 10.5152/dir.2018.17315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.