MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cmpb.2018.05.015

Медицинская библиотека · Computer methods and programs in biomedicine · 2018

State-of-the-art review on automated lumen and adventitial border delineation and its measurements in carotid ultrasound.

Kumar P Krishna, Araki Tadashi, Rajan Jeny, Laird John R, Nicolaides Andrew, Suri Jasjit S, Fellow AIMBE

СтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Accurate, reliable, efficient, and precise measurements of the lumen geometry of the common carotid artery (CCA) are important for (a) managing the progression/regression of atherosclerotic build-up and (b) the risk of stroke. The image-based degree of stenosis in the carotid artery and the plaque burden can be predicted using the automated carotid lumen diameter (LD)/inter-adventitial diameter (IAD) measurements from B-mode ultrasound images. The objective of this review is to present the state-of-the-art methods and systems for the measurement of LD/IAD in CCA based on automated or semi-automated strategies. Further, the performance of these systems is compared based on various metrics for its measurements.

METHODS

The automated algorithms proposed for the segmentation of carotid lumen are broadly classified into two different categories as: region-based and boundary-based. These techniques are discussed in detail specifying their pros and cons. Further, we discuss the challenges encountered in the segmentation process along with its quantitative assessment. Lastly, we present stenosis quantification and risk stratification strategies.

RESULTS

Even though, we have found more boundary-based approaches compared to region-based approaches in the literature, however, the region-based strategy yield more satisfactory performance. Novel risk stratification strategies are presented. On a patient database containing 203 patients, 9 patients are identified as high risk patients, whereas 27 patients are identified as medium risk patients.

CONCLUSIONS

We have presented different techniques for the lumen segmentation of the common carotid artery from B-mode ultrasound images and measurement of lumen diameter and inter-adventitial diameter. We believe that the issue regarding boundary-based techniques can be compensated by taking regional statistics embedded with boundary-based information.

Для цитирования: Kumar P Krishna, Araki Tadashi, Rajan Jeny, Laird John R, Nicolaides Andrew, Suri Jasjit S, Fellow AIMBE. State-of-the-art review on automated lumen and adventitial border delineation and its measurements in carotid ultrasound.. Computer methods and programs in biomedicine. 2018. DOI: 10.1016/j.cmpb.2018.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.