Keratoconus prediction using a finite element model of the cornea with local biomechanical properties.

Carvalho Luis Alberto, Prado Marcelo, Cunha Rodivaldo H, Costa Neto Alvaro, Paranhos Augusto, Schor Paulo, Chamon Wallace

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predict keratoconus-like behavior and its evolution based on material properties of the corneal tissue.

METHODS

Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity.

RESULTS

The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea.

CONCLUSIONS

This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.

Для цитирования: Carvalho Luis Alberto, Prado Marcelo, Cunha Rodivaldo H, Costa Neto Alvaro, Paranhos Augusto, Schor Paulo, Chamon Wallace. Keratoconus prediction using a finite element model of the cornea with local biomechanical properties.. Arquivos brasileiros de oftalmologia. 2009. DOI: 10.1590/s0004-27492009000200002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.