Safety and efficacy of Intacs in Indian eyes with keratoconus: an initial report.
Аннотация
CONTEXT: In contact lens-intolerant keratoconus patients, intrastromal placement of Intacs is becoming a promising new modality of treatment.
AIMS: To study the safety and efficacy of implantation of microthin corneal inserts (Intacs) in Asian-Indian keratoconus patients.
SETTINGS AND
DESIGN
Retrospective interventional case series, in the cornea and refractive surgery service, at a tertiary care eye hospital in South India, between May 2006 and July 2007.
MATERIALS AND
METHODS
Intacs (Addition Technology, USA) were successfully implanted by mechanically creating tunnels, in 12 eyes of 12 keratoconus patients, who were contact lens-intolerant. The patients (mean age 25.58 years, nine male and three female) had a minimum follow-up of six months. Five patients had severe keratoconus (mean K > 53 D) and nine had central cones.
RESULTS
All patients improved or retained visual acuity. The uncorrected visual acuity (UCVA) improved from a mean value of 0.06, (SD +/- 0.08) to 0.19 postoperatively (SD+/- 0.15) ( P = 0.01). The change in mean best corrected visual acuity (BCVA) was from 0.51, (SD +/- 0.24), to 0.69, (SD +/-0.00) ( P = 0.01) postoperatively. The average central keratometry reading was 52.55 D. The change in mean K from 52.84 to 49.16 and 49.15 at one and six months respectively, was statistically significant. We did not have any major intra- or early postoperative complications. Eight of 12 eyes became contact lens-tolerant post-surgery.
CONCLUSION
The procedure of Intacs implantation appears to be safe and effective in a small group of Indian population at an intermediate follow-up.