PURPOSE: To compare accuracy of LASIK flap and INTACS centration following femtosecond laser application in normal and keratoconic eyes.

METHODS

This is a retrospective case series comprising 133 eyes of 128 patients referred for refractive surgery. All eyes were divided into two groups according to preoperative diagnosis: group 1 (LASIK group) comprised 74 normal eyes of 72 patients undergoing LASIK with a femtosecond laser (IntraLase), and group 2 (INTACS group) consisted of 59 eyes of 39 patients with keratoconus for whom INTACS were implanted using a femtosecond laser (IntraLase). Decentration of the LASIK flap and INTACS was analyzed using Pentacam.

RESULTS

Temporal decentration was 612.56 +/- 384.24 microm (range: 30 to 2120 microm) in the LASIK group and 788.33 +/- 500.34 microm (range: 30 to 2450 microm) in the INTACS group. A statistically significant difference was noted between the groups in terms of decentration (P < .05). Regression analysis showed that the amount of decentration of the LASIK flap and INTACS correlated with the central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group, respectively.

CONCLUSIONS

Decentration with the IntraLase occurred in most cases, especially in keratoconic eyes. The applanation performed for centralization during IntraLase application may flatten and shift the pupil center, and thus cause decentralization of the LASIK flap and INTACS. Central corneal thickness in the LASIK group and preoperative sphere and cylinder in the INTACS group proved to be statistically significant parameters associated with decentration.

Для цитирования: Ertan Aylin, Karacal Humeyra. Factors influencing flap and INTACS decentration after femtosecond laser application in normal and keratoconic eyes.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2008. DOI: 10.3928/1081597x-20081001-05.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.