MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2007.06.055

Медицинская библиотека · Journal of cataract and refractive surgery · 2007

Intracorneal ring segment implantation for the management of keratoconus: safety and efficacy.

Zare Mohammad A, Hashemi Hassan, Salari Mohammad R

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the safety and efficacy of intracorneal ring segment (Intacs, Addition Technology, Inc.) implantation in the management of keratoconus.

SETTING

Department of Ophthalmology and Ophthalmic Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.

METHODS

This prospective case series comprised 30 keratoconic eyes (22 patients) with a clear central cornea that had Intacs implantation. All patients were contact-lens intolerant. The main outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, keratometry, and pachymetry. Patients were examined before Intacs implantation as well as 1 week and 1, 3, and 6 months postoperatively.

RESULTS

The mean age of the 5 women and 17 men was 25.9 years +/- 5.29 (SD). The mean UCVA improved from 0.60 +/- 0.311 logMAR preoperatively to 0.29 +/- 0.20 logMAR 6 months postoperatively (P<.001) and the mean BSCVA, from 0.25 +/- 0.16 logMAR to 0.13 +/- 0.14 logMAR, respectively (P<.001). The mean spherical equivalent improved from -6.93 +/- 3.52 diopters (D) preoperatively to -3.23 +/- 2.81 D at 6 months and the mean refractive cylinder, from -4.65 +/- 1.85 D to -3.90 +/- 1.70 D, respectively. The mean keratometry decreased from 49.84 +/- 3.58 D preoperatively to 47.90 +/- 3.58 D postoperatively (P<.001). Three eyes had ring exposure, and 1 eye had bacterial keratitis and ring exposure.

CONCLUSION

Intacs implantation appeared to be effective in improving UCVA and BSCVA in patients with mild to moderate keratoconus and contact-lens intolerance.

Для цитирования: Zare Mohammad A, Hashemi Hassan, Salari Mohammad R. Intracorneal ring segment implantation for the management of keratoconus: safety and efficacy.. Journal of cataract and refractive surgery. 2007. DOI: 10.1016/j.jcrs.2007.06.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.