MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e318055e65c

Медицинская библиотека · Cornea · 2007

Mistaken diagnosis of keratoconus because of corneal warpage induced by hydrogel lens wear.

Tseng Santos Shan-Yu, Hsiao John Ching-Jen, Chang David Chao-Kai

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We report a case of corneal warpage secondary to hydrogel lens wear that was initially mistaken as a case of keratoconus.

METHODS

A 26-year-old Chinese female hydrogel lens wearer presented with an interest in refractive surgery. After topographies and pachymetries were performed, keratoconus was initially diagnosed for her right eye and suspect keratoconus diagnosed for her left eye. This conclusion was felt to be confirmed at a follow-up visit 1 week later, but keratoconus contact lens treatment was delayed because of the presence of superficial punctate keratitis.

RESULTS

After 8 weeks without lens wear, corneal maps were performed again. The maps now showed regular with-the-rule astigmatism, and none of the previous evidence of keratoconus. Central pachymetries were also normal.

CONCLUSIONS

Soft contact lens wear can induce corneal warpage mimicking keratoconus. Had the standard treatment for keratoconus been implemented before resolution of the warpage, it could have proven injurious to the patient, because the treatment itself could have provided an impetus for the protrusion to remain or perhaps even progress. Our case gives clinicians reason to pause when dealing with contact lens wearers presenting with corneal curvature irregularities such as keratoconus or ectasia, because of the possibility of lens-induced warpage.

Для цитирования: Tseng Santos Shan-Yu, Hsiao John Ching-Jen, Chang David Chao-Kai. Mistaken diagnosis of keratoconus because of corneal warpage induced by hydrogel lens wear.. Cornea. 2007. DOI: 10.1097/ico.0b013e318055e65c.