DOI 10.34067/kid.0000000000000513
The Δ Anion Gap/Δ Bicarbonate Ratio in Lactic Acidosis: Time for a New Baseline?
Аннотация
KEY POINTS: The mean delta anion gap (ΔAG)/delta bicarbonate (ΔHCO3) calculated using an albumin-corrected anion gap and each patient's individual baseline AG and serum HCO3 was 1.20. The ΔAG/ΔHCO3 using mean normal AG and serum HCO3 was 1.6–1.8; use of mean normal values can result in misdiagnosis of complex acid-base disorders. The elevated ΔAG/ΔHCO3 is likely due to unmeasured anions.
BACKGROUND
The ratio of delta anion gap and delta bicarbonate (ΔAG/ΔHCO3) is used to detect coexisting acid-base disorders in patients with high anion gap metabolic acidosis. The ΔAG/ΔHCO3 ratio of 1.6–1.8:1 in lactic acidosis is derived from limited data using mean normal values for anion gap (AG) and serum HCO3. The objective of this study was to be the first to examine the ΔAG/ΔHCO3 using each patient's individual baseline AG and serum HCO3.
METHODS
This was a retrospective cohort study of adult intensive care unit (ICU) patients with sepsis. Laboratory data from simultaneously drawn chemistry panel, including anion gap and serum lactate on admission to the ICU, were obtained. Baseline AG, HCO3, and albumin measurements were obtained 1–24 months before ICU admission. The ΔAG/ΔHCO3 was calculated using an albumin-corrected anion gap and each patient's individual baseline AG and serum HCO3.
RESULTS
Three hundred forty-four patients were included. One hundred twenty-eight patients had normal serum lactate levels (≤1.9 mmol/L), and 216 patients had elevated serum lactate levels (>1.9 mmol/L). ΔAG/ΔHCO3 was calculated for the 216 patients who had elevated serum lactate levels (>1.9 mmol/L). The mean ΔAG/ΔHCO3 for all patients with elevated serum lactate levels was 1.20 (SD 1.50).
CONCLUSIONS
The mean ΔAG/ΔHCO3 calculated using an albumin-corrected anion gap and each patient's individual baseline AG and serum HCO3 was 1.20. The ΔAG/ΔHCO3 reported in prior literature that used mean normal AG and serum HCO3 was 1.6–1.8, highlighting that use of mean normal values affects the calculation of the ΔAG/ΔHCO3 and subsequent conclusions about underlying pathophysiology. The use of these mean normal values can result in misdiagnosis of complex acid-base disorders and inappropriate treatment. Our analysis indicates that the elevated ΔAG/ΔHCO3 is likely due to unmeasured anions contributing to an elevation in AG.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.